Effects of Iterative Reconstruction on Image Quality of Pediatric Body Computed Tomography Images

Abstract: This study evaluated the effects of three types of hybrid iterative reconstruction (IR) on image quality of pediatric body computed tomography images. The image quality components evaluated were noise power spectrum (NPS), task-based modulation transfer function (TTF), and system performance function (SPF). As the IR strength was increased while reducing the radiation dose, the NPS increased in a low-frequency range and the TTF decreased in low-contrast regions. In the low-contrast regions, the calculated SPF … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 20 publications
0
1
0
Order By: Relevance
“…IR has the advantages of fewer projections and imaging under conditions of incomplete data and low signal-to-noise ratio, which is currently used in the reduction of image noise in medical equipment and the improvement of image quality, and at the same time decreases the dose of contrast agent [11]. e IR algorithm receives raw data that can characterize X-ray intensity based on the CT detector, finds the individual pixel values in the image matrix, and reduces the human anatomical structure, which can effectively reduce the patient radiation dose during the CT image reconstruction [12], but there is a problem with large image noise, waiting to be further optimized [13].…”
Section: Introductionmentioning
confidence: 99%
“…IR has the advantages of fewer projections and imaging under conditions of incomplete data and low signal-to-noise ratio, which is currently used in the reduction of image noise in medical equipment and the improvement of image quality, and at the same time decreases the dose of contrast agent [11]. e IR algorithm receives raw data that can characterize X-ray intensity based on the CT detector, finds the individual pixel values in the image matrix, and reduces the human anatomical structure, which can effectively reduce the patient radiation dose during the CT image reconstruction [12], but there is a problem with large image noise, waiting to be further optimized [13].…”
Section: Introductionmentioning
confidence: 99%