2013 Kansas City, Missouri, July 21 - July 24, 2013 2013
DOI: 10.13031/aim.20131593447
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Manure Managements on Ammonia, Hydrogen Sulfide and Greenhouse Gases Emissions from the Naturally Ventilated Dairy Barn

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The very long effective path length of the light in the cavity (e.g., over 20 km for 25 cm cavity; Picarro, 2017) enables a significantly higher sensitivity compared to conventional absorption spectroscopy (Berden et al, 2000;von Bobrutzki et al, 2010). There is negligible interference from VOCs on CRDS measurements, which makes CRDS ideal for measuring NH 3 concentrations in this setting (Kamp et al, 2019). A G2103 Analyzer (Picarro Inc., Sunnyvale, CA, USA) using the CRDS technique was applied in this study for the test of ammonia laboratory calibration and the effect of nontargeted VOCs on ammonia measurement.…”
Section: Instrumentation For Gas Concentrations Measurementmentioning
confidence: 99%
See 2 more Smart Citations
“…The very long effective path length of the light in the cavity (e.g., over 20 km for 25 cm cavity; Picarro, 2017) enables a significantly higher sensitivity compared to conventional absorption spectroscopy (Berden et al, 2000;von Bobrutzki et al, 2010). There is negligible interference from VOCs on CRDS measurements, which makes CRDS ideal for measuring NH 3 concentrations in this setting (Kamp et al, 2019). A G2103 Analyzer (Picarro Inc., Sunnyvale, CA, USA) using the CRDS technique was applied in this study for the test of ammonia laboratory calibration and the effect of nontargeted VOCs on ammonia measurement.…”
Section: Instrumentation For Gas Concentrations Measurementmentioning
confidence: 99%
“…A G2103 Analyzer (Picarro Inc., Sunnyvale, CA, USA) using the CRDS technique was applied in this study for the test of ammonia laboratory calibration and the effect of nontargeted VOCs on ammonia measurement. The accuracy of the CRDS instrument is routinely checked against a certified reference gas as described by Kamp et al (2019). The CRDS analyzer was equipped with two in-line, sub-micron poly-tetrafluoroethylene (PTFE) particulate matter filters: one at the gas inlet at the back of the analyzer and one at the inlet of the cavity to protect the highly reflective mirrors.…”
Section: Instrumentation For Gas Concentrations Measurementmentioning
confidence: 99%
See 1 more Smart Citation