1969
DOI: 10.2514/3.62805
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Polymer Addition on Friction in a 10-in.-Diam Pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

1974
1974
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 5 publications
0
2
0
1
Order By: Relevance
“…Forester et al [110] analyzed the effect of a polymeric additive on DR in a pipe flow (where the pipe diameter was 254 mm), and suggested the potential application of drag reduction to sewer systems. Experimental evidence suggested that the discharge capacities of sewers can be Recently, Ueberschar et al [101] compared the fluid friction of single micrometer-sized blank and DNA-grafted PS microspheres under shear flow, and found that a thick DNA brush layer grafted onto PS microspheres reduced the frictional drag significantly, especially in dilute λ-DNA solution.…”
Section: Applications Of Polymer-induced Drag Reductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Forester et al [110] analyzed the effect of a polymeric additive on DR in a pipe flow (where the pipe diameter was 254 mm), and suggested the potential application of drag reduction to sewer systems. Experimental evidence suggested that the discharge capacities of sewers can be Recently, Ueberschar et al [101] compared the fluid friction of single micrometer-sized blank and DNA-grafted PS microspheres under shear flow, and found that a thick DNA brush layer grafted onto PS microspheres reduced the frictional drag significantly, especially in dilute λ-DNA solution.…”
Section: Applications Of Polymer-induced Drag Reductionmentioning
confidence: 99%
“…Forester et al [110] analyzed the effect of a polymeric additive on DR in a pipe flow (where the pipe diameter was 254 mm), and suggested the potential application of drag reduction to sewer systems. Experimental evidence suggested that the discharge capacities of sewers can be increased significantly by appropriate polymer dosing.…”
Section: Applications Of Polymer-induced Drag Reductionmentioning
confidence: 99%
“…La figure 13, d'après la référence [29], montre que pour une conduite de 254 mm, la réduction de frottement maximale n'est que de 38 %, bien infé-rieure à celle observée dans des tubes de très petit diamètre (figure 1). D'autre part, aucune réduction de frottement n'apparait avant d'avoir atteint des nombres de Reynolds de l'ordre de 60 000, bien supérieurs aux seuils mis en évidence dans les petits diamètres.…”
Section: Polyox Wsr 301unclassified