2009
DOI: 10.1369/jhc.2009.953877
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Prolonged Formalin Fixation on Diagnostic Immunohistochemistry in Domestic Animals

Abstract: S U M M A R Y Immunohistochemistry (IHC) is routinely used in diagnostic pathology to detect infectious agents, to immunophenotype neoplastic cells, and to prognosticate neoplastic diseases. Formalin fixation is considered a limiting factor for IHC because formalin can cross-link antigens and mask epitopes. Prolonged formalin fixation is presumed to result in decreased antigen detection; however, this effect has only been evaluated with a few antibodies. The goal of this study was to evaluate the effect of pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

7
104
2
4

Year Published

2010
2010
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 102 publications
(117 citation statements)
references
References 24 publications
7
104
2
4
Order By: Relevance
“…In our experience, immunoreactivity for all the markers examined is not significantly affected by formalin fixation up to 1 month. 62 For CD34, immunoreactivity is not reduced in tissues fixed for at least 2 weeks (personal observations). When multiple slides of the same tumor were available, the most representative sample was selected by 1 author (J.A.R.).…”
Section: Methodsmentioning
confidence: 97%
“…In our experience, immunoreactivity for all the markers examined is not significantly affected by formalin fixation up to 1 month. 62 For CD34, immunoreactivity is not reduced in tissues fixed for at least 2 weeks (personal observations). When multiple slides of the same tumor were available, the most representative sample was selected by 1 author (J.A.R.).…”
Section: Methodsmentioning
confidence: 97%
“…3). 288,297,403,404 Automated stainers are designed to duplicate manual procedures and ensure uniform application of each step of the process. Thus, the use of automated equipment creates a uniform and standardized testing environment, which will improve intralaboratory run-to-run consistency.…”
Section: Assay Validationmentioning
confidence: 99%
“…205 However, significant reduction of immunoreactivity is detected in only a few markers after several weeks' fixation ( Fig. 3), 238,403,404 so it seems that the negative effects of overfixation are antigen and antibody dependent and can be overcome in many instances with an appropriate antigen retrieval procedure. 6,22,164,242 Vimentin was once used as an internal control of antigenicity loss in overfixed tissues.…”
mentioning
confidence: 99%
“…A coloração de ZN mostrou distribuição semelhante à observada na IHQ, porém os anticorpos comerciais existentes não distinguem os diferentes tipos de micobactérias, com reações cruzadas entre elas (micobactérias tuberculosas, micobactérias não tuberculosas e bacilos da lepra) (Alves et al 1999). O tempo de fixação em formol é considerado um fator limitante na técnica de IHQ, pois a fixação prolongada em formalina pode resultar em falha de detecção do antígeno (Webster et al 2009). Esta situação não foi evidenciada no presente estudo, visto que houve imunomarcação na maioria dos casos.…”
Section: Discussionunclassified