2021
DOI: 10.1016/j.ultsonch.2020.105445
|View full text |Cite
|
Sign up to set email alerts
|

Effects of sonochemical approach and induced contraction of core–shell bismuth sulfide/graphitic carbon nitride as an efficient electrode materials for electrocatalytic detection of antibiotic drug in foodstuffs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 40 publications
(13 citation statements)
references
References 44 publications
0
13
0
Order By: Relevance
“…Despite the fact that at most reported electrodes CAP electrochemistry followed the same pathway [ 50 , 58 , 60 , 61 , 62 , 65 , 66 , 67 , 74 , 83 , 84 , 89 , 93 , 94 , 97 , 110 , 111 , 113 , 115 ], the corresponding signals were shifted within some limits of about 0.200–0.300 V as can be observed from Figure 3 . On the other hand, the peak current variation with the scan rate emphasized that at some electrodes CAP reduction was diffusion controlled [ 5 , 50 , 57 , 60 , 61 , 62 , 74 , 84 , 89 , 90 , 91 , 110 , 111 , 112 , 113 ], whereas in other cases the electrode process was governed by the CAP adsorption on the sensor surface [ 55 , 65 , 66 , 67 , 72 , 83 , 87 , 94 , 97 , 105 , ...…”
Section: Principles Of Amphenicol Electrochemical Detectionmentioning
confidence: 93%
See 4 more Smart Citations
“…Despite the fact that at most reported electrodes CAP electrochemistry followed the same pathway [ 50 , 58 , 60 , 61 , 62 , 65 , 66 , 67 , 74 , 83 , 84 , 89 , 93 , 94 , 97 , 110 , 111 , 113 , 115 ], the corresponding signals were shifted within some limits of about 0.200–0.300 V as can be observed from Figure 3 . On the other hand, the peak current variation with the scan rate emphasized that at some electrodes CAP reduction was diffusion controlled [ 5 , 50 , 57 , 60 , 61 , 62 , 74 , 84 , 89 , 90 , 91 , 110 , 111 , 112 , 113 ], whereas in other cases the electrode process was governed by the CAP adsorption on the sensor surface [ 55 , 65 , 66 , 67 , 72 , 83 , 87 , 94 , 97 , 105 , ...…”
Section: Principles Of Amphenicol Electrochemical Detectionmentioning
confidence: 93%
“…Thus, for example, in the first approach a thin film was formed by dropping an ethanolic graphene nanoflakes dispersion [ 50 ], a polydopamine functionalized vapor-grown carbon fiber composite slurry [ 94 ], DMF suspension of Co 3 O 4 @rGO [ 58 ] or of graphene/copper phtalocyanine [ 62 ], a solution containing gold nanoflowers, N-hydroxysuccinimide and graphene oxide [ 107 ], a dispersion in DMF of the nanocomposite carbon nanotubes/ethylene diamine/gold nanoparticles [ 118 ], Gd 2 (MoO 4 ) 3 @rG slurry in isopropyl alcohol and Milli-Q water [ 57 ], ZnWO 4 nanowires [ 90 ] or GO/PdNPs [ 66 ] ethanolic suspension, dispersion of Eu 2 O 3 NPs@rGO in water:ethanol [ 111 ] or of Fe/NC in deionized water:isopropyl alcohol:Nafion [ 88 ] on the electrode surface. This step was followed by drying in ambient conditions [ 50 , 57 , 65 , 66 , 88 , 94 , 105 , 107 , 111 , 113 ], at higher temperatures [ 59 , 61 , 84 , 112 ] or under vacuum [ 62 ].…”
Section: Procedures For the Preparation Of Electrochemical Devices Fo...mentioning
confidence: 99%
See 3 more Smart Citations