2021
DOI: 10.1177/01617346211010488
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of High Temporal Frequency Photoacoustic Guidance of Laser Ablation Procedures

Abstract: Inaccurate placement of the ablation catheter and the inability to monitor the real-time temperature within the tissue of interest such as veins curbs the treatment efficacy of laser ablation procedures during thermal therapies. Our previous studies have validated the efficacy of photoacoustic (PA) imaging during endovenous laser ablation (EVLA) procedures. However, the PA-guided therapies suffer from low temporal resolution, due to the low pulse repetition rates of pulsed lasers, which could cause a problem d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 34 publications
(52 reference statements)
0
4
0
Order By: Relevance
“…Inaccuracies induced by low PA imaging frame rates can generate a non-uniform ablation pattern and cause the recurrence of the malady being treated. The low energy of pulsed lasers for integrated PA imaging and ablation catheters provides an opportunity to use higher repetition rate lasers such as diode-pumped solid-state (DPSS) lasers at higher pulse repetition rates [ 74 ]. The high repetition rate of PA imaging detected more intermediate positions of the ablation catheter tip, improving the system’s temporal resolution and providing more precise tracking of the ablation catheter tip.…”
Section: Importance Of High Temporal Resolution In Pa-guided Ablation...mentioning
confidence: 99%
See 1 more Smart Citation
“…Inaccuracies induced by low PA imaging frame rates can generate a non-uniform ablation pattern and cause the recurrence of the malady being treated. The low energy of pulsed lasers for integrated PA imaging and ablation catheters provides an opportunity to use higher repetition rate lasers such as diode-pumped solid-state (DPSS) lasers at higher pulse repetition rates [ 74 ]. The high repetition rate of PA imaging detected more intermediate positions of the ablation catheter tip, improving the system’s temporal resolution and providing more precise tracking of the ablation catheter tip.…”
Section: Importance Of High Temporal Resolution In Pa-guided Ablation...mentioning
confidence: 99%
“…The high repetition rate of PA imaging detected more intermediate positions of the ablation catheter tip, improving the system’s temporal resolution and providing more precise tracking of the ablation catheter tip. We have previously demonstrated using a 500 Hz laser (NL 204-1K-SH, EKSPLA) to enhance PA thermometry accuracy during ablation [ 74 ]. The fast PA-guided laser ablation system provided more accurate feedback about the rapid temperature variations in increments of 100 °C per 250 ms.…”
Section: Importance Of High Temporal Resolution In Pa-guided Ablation...mentioning
confidence: 99%
“…The spectrograms show the information of the signals along with both the frequency domain and time domain. The IBM was calculated according to the spectrogram of M-E DAS and equation (1). A binary matrix was created at the same size as the spectrogram.…”
Section: Signal Processingmentioning
confidence: 99%
“…Photoacoustic (PA) imaging [1][2][3] plays a promising role in medical diagnosis. Especially for functional imaging, it owns potential value in melanoma detection, [4][5][6] breast cancer detection, 7,8 vasculature imaging, [9][10][11] and molecular imaging.…”
Section: Introductionmentioning
confidence: 99%