1984
DOI: 10.1016/0009-8981(84)90138-4
|View full text |Cite
|
Sign up to set email alerts
|

Efficacy of latex agglutination and quantification methods for determination of C-reactive protein (CRP) in pediatrie sera

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

1985
1985
2015
2015

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 15 publications
0
12
0
Order By: Relevance
“…Laboratory assessment included complete blood count [Coulter 1660], C-reactive protein [AVITEX- CRP latex test [23]], ESR [Westergren method [24]], serum calcium [colorimetric method [25]], serum alkaline phosphatase [autoanalyzer], serum phosphorus [direct UV method without reduction [26]] and urinary phosphorus [colorimetric methods using an autoanalyzer (Multistat III Plus, Instrumentation Laboratory, Inc, Lexington, MA)]. Colonoscopy and esophago-gastrodudenoscopy [Pentax videosopes, PENYAX GmbH CO. Juulius Vosseler Strasse 104, 22527 Hamburg, Germany] with histopathologic assessment of multiple biopsies were done for all patients.…”
Section: Methodsmentioning
confidence: 99%
“…Laboratory assessment included complete blood count [Coulter 1660], C-reactive protein [AVITEX- CRP latex test [23]], ESR [Westergren method [24]], serum calcium [colorimetric method [25]], serum alkaline phosphatase [autoanalyzer], serum phosphorus [direct UV method without reduction [26]] and urinary phosphorus [colorimetric methods using an autoanalyzer (Multistat III Plus, Instrumentation Laboratory, Inc, Lexington, MA)]. Colonoscopy and esophago-gastrodudenoscopy [Pentax videosopes, PENYAX GmbH CO. Juulius Vosseler Strasse 104, 22527 Hamburg, Germany] with histopathologic assessment of multiple biopsies were done for all patients.…”
Section: Methodsmentioning
confidence: 99%
“…munoassay (PCIA) with a sensitivity of 1 nglml (81), (2) spot immunoprecipitate assay (SIA) with a sensitivity of 1-.25 pg/rnl (82), and (3) immunoradiometric assay (IRMA) with a detection range of from 1 ng/ml to lOpJml (83). Each of these methods has advantages and disadvantages in its application in the clinical laboratory.…”
Section: Source Of Crp and Normal Valuesmentioning
confidence: 99%
“…The CRP-Latex test is a rapid agglutination procedure for the direct determination of CRP on slides by semi quantitative method [19]. Human CRP antibodies agglutinate in the presence of CRP in patient's serum.…”
Section: Methodsmentioning
confidence: 99%