1988
DOI: 10.1109/59.43179
|View full text |Cite
|
Sign up to set email alerts
|

Efficient bounding method for linear contingency analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
0
2

Year Published

1995
1995
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 118 publications
(46 citation statements)
references
References 7 publications
0
44
0
2
Order By: Relevance
“…Antar Muka PowerWorld Simulator 15 GSO N3 = beberapa bus yang membatasi N1 dan N2 Perubahan maksimum pada perbedaan sudut fasa adalah (8) atau (9) dan (10) Sehingga dapat dikembangkan teorema yakni [10]: (11) dimana i dan j adalah pasangan bus di N3, Δθi adalah Δθ terbesar di N3 dan Δθj adalah Δθ terkecil di N3. Dengan menggabungkan (10) dan (11), diperoleh [2]: (12) Semua rangkaian di N2 dapat bebas dari overload jika nilai IΔθi -ΔθjI kecil dari pada nilai terkecil terhadap semua pasangan pq [2].…”
Section: Metode Boundingunclassified
“…Antar Muka PowerWorld Simulator 15 GSO N3 = beberapa bus yang membatasi N1 dan N2 Perubahan maksimum pada perbedaan sudut fasa adalah (8) atau (9) dan (10) Sehingga dapat dikembangkan teorema yakni [10]: (11) dimana i dan j adalah pasangan bus di N3, Δθi adalah Δθ terbesar di N3 dan Δθj adalah Δθ terkecil di N3. Dengan menggabungkan (10) dan (11), diperoleh [2]: (12) Semua rangkaian di N2 dapat bebas dari overload jika nilai IΔθi -ΔθjI kecil dari pada nilai terkecil terhadap semua pasangan pq [2].…”
Section: Metode Boundingunclassified
“…On the other hand, Q is more sensitive to the change of V. Due to this coupling characteristics, (2) can be simplified into: (3) This lead to decoupled equations:…”
Section: Fast Decoupled Methodsmentioning
confidence: 99%
“…These techniques go under the name of concentric relaxation [2], bounding method for AC contingency screening [3,4] and artificial intelligent based method [5]. The problem of these techniques is requires more layer and consumed longer computing time.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, the extra computational effort is brought into the evaluation procedure. Furthermore, the implementation of this method is based on the DC power flow model, which cannot check the voltage and reactive power of the power supply at load points and capture the effects of voltage and reactive power supplies on system reliability Reduction of State Space by the Contingency Selection Method In adequacy assessment, an important fact is that many component outages (contingencies) do not cause the service curtailment or other adverse impact on service quality [47][48][49]. The contingency selection method can eliminate states whose impact on the system is small, thus reducing the state space to include only states whose impact on the system is significant.…”
Section: Adequacy Evaluationmentioning
confidence: 99%