2021
DOI: 10.1088/1755-1315/738/1/012034
|View full text |Cite
|
Sign up to set email alerts
|

Efficient Lighting Design for Multiuse Architecture Studio Classroom using Dialux Evo 9

Abstract: Both natural and artificial lighting plays an important role in everyday human activities. Natural lighting conditions are responsible for energy consumption in buildings, where lack of natural lighting can increase electricity consumption for artificial lighting. The architectural studio classroom at the Department of Architecture, Universitas Trisakti, requires sufficient illumination so that room users able to do hand drawing, digital drawing, and lecture activities comfortably. To achieve such visual comfo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 6 publications
0
6
0
1
Order By: Relevance
“…Each Studio uses Philips TMS022 2x36W 2xTL-D36W/840 HF Standard +GMS022 R lamps in terms of artificial lighting. The number of lamps in studio 1 is eight, and studio 2 is six [8]. Based on the analysis of the lighting level on its suitability as a drawing-room in SNI 03-6197-2011 (Table 1), it is known that the level of lighting in the architectural Studio of UNISA Yogyakarta is still not appropriate (below the standard recommended by SNI).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Each Studio uses Philips TMS022 2x36W 2xTL-D36W/840 HF Standard +GMS022 R lamps in terms of artificial lighting. The number of lamps in studio 1 is eight, and studio 2 is six [8]. Based on the analysis of the lighting level on its suitability as a drawing-room in SNI 03-6197-2011 (Table 1), it is known that the level of lighting in the architectural Studio of UNISA Yogyakarta is still not appropriate (below the standard recommended by SNI).…”
Section: Resultsmentioning
confidence: 99%
“…Artificial lighting needs to be considered because it can increase the lighting level and shape the room's atmosphere [7]. Suppose the room has sufficient illuminance from natural lighting, energy consumption for artificial lighting [8]. The need for light in the room cannot be negotiated.…”
Section: Methodsmentioning
confidence: 99%
“…The simulation was carried out using DIALux 4.12 software. The simulation using DIAlux software has been commonly used and implemented in the study for evaluating lighting efficiency for indoor and outdoor lighting, which has become a de facto standard [33], [34]. The simulation process for tunnel lighting using DIALux software and data collected from the Cisumdawu tunnel involves:…”
Section: Methodsmentioning
confidence: 99%
“…Software DIALux memudahkan perencana untuk menciptakan lingkungan virtual baik siang hari maupun malam hari dengan cahaya buatan serta mensimulasikan bangunan, ruangan, dan menganalisis kinerja sistem pencahayaan di lokasi geografis dan lingkungan objek tertentu. Keluaran software DIALux berupa angka, grafik, dan gambar dan dapat memberikan gambaran yang cukup untuk menggambarkan situasi pencahayaan yang optimal [4].…”
Section: Pendahuluanunclassified