A unconventional stirred tank of geometry typically adopted
for
the production of biogas is experimentally investigated with pseudo-plastic
model fluids. The apparent viscosities of the fluids, based on the
Metzner–Otto method, are in the range of 39–264 mPa·s,
resulting in a range of rotational Reynolds number equal to 17–648.
The power consumption of the three top-entering agitators is measured
by a strain gauge technique, and the power number curve is obtained
in the full range of flow regimes, going from laminar to fully turbulent
conditions. The flow field measured by particle image velocimetry
allows us to observe the fluid circulation patterns and their variations
in different operative conditions. The measurements reveal relatively
low axial and radial velocities, especially toward the bottom of the
tank, that may hinder solid feedstock suspension and subsequent biogas
production. Significant changes in the flow patterns are observed
with small variations in the impeller speed and the mixture viscosity.
The homogenization dynamics of a tracer obtained by planar laser-induced
fluorescence leads us to estimate the dimensionless mixing time, a
trend similar to that observed for conventional stirred vessel geometries.
The detailed fluid dynamics information collected by a combination
of different techniques can contribute to optimize the energy requirement
and to avoid failure of the biogas production due to poor fluid mixing.