2000
DOI: 10.1109/58.818772
|View full text |Cite
|
Sign up to set email alerts
|

Elastic, piezoelectric, and dielectric properties of 0.955Pb(Zn/sub 1/3/Nb/sub 2/3/)O/sub 3/-0.45PbTiO/sub 3/ single crystal with designed multidomains

Abstract: The elastic, piezoelectric, and dielectric properties of a 0.955Pb(Zn(1/3)Nb(2/3))O(3)-0.045PbTiO(3 ) (PZN-4.5%PT) multi-domain single crystal, poled along [001] of the original cubic direction, have been determined experimentally using combined resonance and ultrasonic methods. At room temperature, the PZN-4.5%PT single crystal has rhombohedral symmetry. After being poled along [001], four degenerate states still remain. Statistically, such a domain-engineered crystal may be treated as having an average tetra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
100
0

Year Published

2003
2003
2024
2024

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 157 publications
(104 citation statements)
references
References 9 publications
4
100
0
Order By: Relevance
“…[1][2][3][4][5][6][7][8][9][10][11][12] In modern device design, finite element software packages are routinely used, which need to have the complete set of material properties of constituent materials as input. The accuracy of these material constants determines the accuracy of the design simulation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3][4][5][6][7][8][9][10][11][12] In modern device design, finite element software packages are routinely used, which need to have the complete set of material properties of constituent materials as input. The accuracy of these material constants determines the accuracy of the design simulation.…”
Section: Introductionmentioning
confidence: 99%
“…[2][3][4][5][6][7][8] It is worth mentioning that better accuracy could be obtained by ultrasonic method than the resonance method. 6,14 But only a few independent constants can be measured from one sample by the pulse-echo ultrasonic method.…”
Section: Introductionmentioning
confidence: 99%
“…[7][8][9][10]. For characterization of 4mm piezoelectric crystals, five samples are usually employed: (1) …”
Section: Combined Ultrasonic-resonant Methodsmentioning
confidence: 99%
“…Following the same argument in previous studies [1][2][3][4][5][6][7][8][9], we treat the [0 0 1] poled PZN-PT and PMN-PT single crystals as pseudo-tetragonal with 4mm domain pattern symmetry. The fourfold axis is along the poling direction, i.e., [0 0 1] direction of parent cubic system.…”
Section: Measurement Proceduresmentioning
confidence: 99%
“…10 First, perovskite crystals, in general, possess the highest elastic stiffness constant c 33 D along the pseudo-cubic h111i body diagonals, since the anisotropy factor A [A ¼ 2c 44 /(c 11 -c 12 )] 11 is larger than 1, as given in Table I. 10,[12][13][14] Therefore, perovskite crystals oriented along the [111] direction are selected to achieve a high frequency constant N 33 . Second, the special ferroelectric phase for [111]-oriented crystals, in which high dielectric permittivities present, must be identified.…”
Section: Introductionmentioning
confidence: 99%