Electric field calculation around of overhead transmission lines in Bosnia and Herzegovina

Abstract: Paper presents a calculation of the electric field distribution around the 400 kV transmission lines in power system of Bosnia and Herzegovina (B&H). Method of equivalent charges was used for the calculation of the electric field at arbitrary points in the vicinity of high-voltage transmission lines. Transmission lines with standard tower′s dimensions, as well as lines with reduced (compact) tower′s dimensions were considered. Comparisons between calculated and measured results of electric field values around … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
13
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 8 publications
1
13
0
1
Order By: Relevance
“…Content may change prior to final publication. 4: The distances between the point charges, the image of point charges and an arbitrary point [34].…”
Section: ) Magnetic Induction Calculation Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Content may change prior to final publication. 4: The distances between the point charges, the image of point charges and an arbitrary point [34].…”
Section: ) Magnetic Induction Calculation Methodsmentioning
confidence: 99%
“…Since the reference case uses bundle conductors composed of two sub-conductors, it is possible to determine the radius of an equivalent conductor. The radius of the equivalent conductor is defined by the following equation [34]:…”
Section: Electric Field Intensity and Magnetic Induction Calculationmentioning
confidence: 99%
See 2 more Smart Citations
“…Мається на увазі метод еквівалентних зарядів, який завдяки своїй відносній простоті та достатньої точності одержав широке поширення на практиці розрахунків електричних полів повітряних ліній електропередачі змінного струму [13]. Згідно з цим методом розрахунок виконується для площини, проведеної нормально до на-пряму траси повітряної лінії електропередачі в середині прогону, тобто там, де завдяки провисанню проводів, відстань від них до землі є найменшою, а, відповідно, напруженість електричного поля біля поверхні землі є максимальною.…”
Section: матеріали та методи дослідження електричного поля повітрянихunclassified