Electrical conductivity measurements on disk-shaped samples

Abstract: We have developed a sample holder design that allows for electrical conductivity measurements on a disk-shaped sample. The sample holder design is based on and compatible with popular measurement systems that are currently restricted to bar-shaped samples. The geometrical correction factors which account for the adjusted measurement configuration were calculated using finite element modeling for a broad range of sample and measurement geometries. We also show that the modeling results can be approximated by a … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…Our current in-house developed apparatus for measuring thermoelectric properties at room temperature is named THEMA (THermo Electric Measuring Apparatus, Figure 5a). The methodology of this apparatus was inspired by the work of de Boor [26]. The apparatus comprises two Peltier modules (one for heating and one for cooling) utilized to create a temperature gradient across the sample.…”
Section: Apparatus Used For Measuring Seebeck Coefficient At Room Tem...mentioning
confidence: 99%
“…Our current in-house developed apparatus for measuring thermoelectric properties at room temperature is named THEMA (THermo Electric Measuring Apparatus, Figure 5a). The methodology of this apparatus was inspired by the work of de Boor [26]. The apparatus comprises two Peltier modules (one for heating and one for cooling) utilized to create a temperature gradient across the sample.…”
Section: Apparatus Used For Measuring Seebeck Coefficient At Room Tem...mentioning
confidence: 99%
“…23 In our setup, electrode pads were clamped tightly onto both ends of the sample, of which the temperature gradients were controlled by S-type thermocouples and micro-heaters. Benefiting from the conventional bar-shaped geometry, the electrical conductivity of samples was directly determined using the standard four-point probe (4PP) method without the need for further mechanical cutting or geometrical correction factor calculations, 24 which are required for 4PP conductivity measurements in disk-shaped bodies. To study the relationship between compressive force/pressure and interfacial contact resistance, the external force exerted on the electrode/ZnO/electrode system was monitored using a homemade apparatus composed of a set of high-precision load cells in Wheatstone bridge configuration, wherein the collected analog output signals were converted to 24-bit digital values via the A/D chip and readout circuit.…”
Section: Samples Characterizationmentioning
confidence: 99%