1997
DOI: 10.1007/bf02080462
|View full text |Cite
|
Sign up to set email alerts
|

Electrically-elicited surface mechanomyogram in myotonic dystrophy

Abstract: The differences between the MMGs of MyD patients and C support the hypothesis that, together with the well-known changes in sarcolemmal excitability, an alteration in electromechanical coupling and a failure in contractile machinery may coexist in MyD.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
71
0
2

Year Published

2000
2000
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 50 publications
(75 citation statements)
references
References 15 publications
2
71
0
2
Order By: Relevance
“…In agreement with previous investigations [35,36], maximum electrically evoked and voluntary strength were significantly lower in DM1 than in HC in both muscles. Lower EMG and MMG amplitude parameters values accompanied this force deficit in patients with DM1.…”
Section: Emg Mmg and F Parameterssupporting
confidence: 93%
See 3 more Smart Citations
“…In agreement with previous investigations [35,36], maximum electrically evoked and voluntary strength were significantly lower in DM1 than in HC in both muscles. Lower EMG and MMG amplitude parameters values accompanied this force deficit in patients with DM1.…”
Section: Emg Mmg and F Parameterssupporting
confidence: 93%
“…Based on previous investigations by our group [35,36] and on preliminary data, a sample size of 13 participants was selected to ensure a statistical power higher than 0.80, with a type 1 error <0. [38].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The illustrative placement using MMG sensors and EMG electrodes is represented in Figure 7 where the MMG sensor is positioned between the EMG electrodes; this placement results in increasing the distance between the electrodes, therefore, they were cut proximally to make them as close as possible. Orizio et al (1997) defines "electromechanical delay" (EMD) as the time interval between the instants at which the EMG and the MMG surpassed the threshold of their average resting values (three standard deviations). In other words, the EMD is the existing time delay between the onset of neuromuscular electrical activation, mechanical myofiber activation and the onset of force development.…”
Section: Clinical Assessment and Rehabilitation Biofeedbackmentioning
confidence: 99%