2015
DOI: 10.1016/j.msec.2015.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Electrocatalytic boost up of epinephrine and its simultaneous resolution in the presence of serotonin and folic acid at poly(serine)/multi-walled carbon nanotubes composite modified electrode: A voltammetric study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 55 publications
(15 citation statements)
references
References 49 publications
0
14
1
Order By: Relevance
“…Using GCE-MWCNT/ZnO/Nc, GCE-MWCNT/ZnO/29H,31H-Pc, GCE-MWCNT/Fe 3 O 4 /Nc, and GCE-MWCNT/Fe 3 O 4 /29H,31H-Pc electrodes in a DPV experiment, LOD of 7.6, 6.5, 12.3, and 4.6 µM, respectively, were obtained. However, the LOD is very high compared to the value reported by Narayana et al [227]…”
Section: Cnts Enhanced Electrochemical Ep Detection (2014-2016)mentioning
confidence: 62%
See 2 more Smart Citations
“…Using GCE-MWCNT/ZnO/Nc, GCE-MWCNT/ZnO/29H,31H-Pc, GCE-MWCNT/Fe 3 O 4 /Nc, and GCE-MWCNT/Fe 3 O 4 /29H,31H-Pc electrodes in a DPV experiment, LOD of 7.6, 6.5, 12.3, and 4.6 µM, respectively, were obtained. However, the LOD is very high compared to the value reported by Narayana et al [227]…”
Section: Cnts Enhanced Electrochemical Ep Detection (2014-2016)mentioning
confidence: 62%
“…A robust poly(serine)/MWCNT composite modified GCE was fabricated for the electrocatalytic boost-up of EP and its detection in the presence of SE and folic acid (FA) by Narayana et al in 2015. [227] The electrode tagged poly(ser)/MWCNT/GCE was fabricated by the electropolymerization of serine on a MWCNT/GCE electrode. When compared with bare GCE and MWCNT/GCE, the manufactured electrode gave the best EP redox peak current and the lowest R tc with CV and EIS, respectively.…”
Section: Cnts Enhanced Electrochemical Ep Detection (2014-2016)mentioning
confidence: 99%
See 1 more Smart Citation
“…The surface area results divulge that the MWCNT/graphene/GCE has more active surface area than MWCNT/GCE and bare GCE. The active surface area of different electrodes was found to be as 2.42 × 10 ‐5 cm 2 for bare GCE, 4.61 × 10 ‐5 cm 2 for graphene/GCE and 10.31 × 10 ‐5 cm 2 for MWCNT/graphene/GCE respectively, suggesting that the electrochemical redox behavior was more favor at MWCNT/graphene/GCE …”
Section: Methodsmentioning
confidence: 99%
“…CVs were recorded for 1mM GA in pH‐6.0, using MWCNT/graphene/GCE as working electrode at different days. There was no considerable change in the current responses of the CVs indicating the excellent stability of the developed method …”
Section: Methodsmentioning
confidence: 99%