2005
DOI: 10.1007/s11175-005-0160-6
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Characteristics of Poly(o-Aminobenzoic Acid) Modified Glassy-Carbon Electrode and Its Electrocatalytic Activity towards Oxidation of Epinephrine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
4
1

Year Published

2006
2006
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 27 publications
3
4
1
Order By: Relevance
“…From the second cycle, two anodic peaks appear on the voltammograms with potentials at +0.145 and +1.588 V, respectively. The peaks' current increased upon continuous scanning, reflecting the continuous growth of the film of polymerization, and a blue polymer film is formed on the GCE surface, which is similar with the former literatues 28, 31. These facts indicate that p ‐ABA is deposited on the surface of GCE by electropolymerization.…”
Section: Resultssupporting
confidence: 67%
See 1 more Smart Citation
“…From the second cycle, two anodic peaks appear on the voltammograms with potentials at +0.145 and +1.588 V, respectively. The peaks' current increased upon continuous scanning, reflecting the continuous growth of the film of polymerization, and a blue polymer film is formed on the GCE surface, which is similar with the former literatues 28, 31. These facts indicate that p ‐ABA is deposited on the surface of GCE by electropolymerization.…”
Section: Resultssupporting
confidence: 67%
“…Xu et al reported a poly‐( p ‐aminobenzoic acid) modified electrode for selective determination of dopamine29 and monoamine 30. Chen et al prepared a poly‐( o ‐Aminobenzoic Acid) modified glassy‐carbon electrode and applied it for the electrochemical determination of epinephrine 31…”
Section: Introductionmentioning
confidence: 99%
“…Comparing CV technique, the sensitivity in semi-derivative SWVs towards AA is very high and the sensitivities of EP and DA have been reduced. Further, the peak separation between the analytes in AA-EP and AA-DA mixture is found to be 180.6 and 166.8 mV, respectively, which is higher than that of the peak separation obtained using CV technique and also higher than the previously reported values [53][54][55]. However, there is a slight lower positive potential shift for all the peaks in semi-derivative SWVs when comparing CVs, this could be caused by the inability to match the backgrounds or by unknown synergistic effects in the mixture [56].…”
Section: Semi-derivative Swvs Of Aa-ep and Aa-da In The Mixture Of Recontrasting
confidence: 71%
“…As reported in literature 2224, a signal amplification based on silver staining on the gold nanoparticles, offers a distinct enhancement of the immunoreaction response, comparing with conventional electrochemical immunosensors.…”
Section: Introductionmentioning
confidence: 90%