2016
DOI: 10.1002/elan.201600559
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Characterization of the Microfabricated Electrochemical Sensor‐Array System

Abstract: Microfabrication technology has been used to prepare a microchip sensor‐array with six sets of platinum electrodes. Chromium/platinum (10 nm/100 nm thick) were sputtered on a borosilicate wafer and patterned by wet etching method. The electrodes were designed with working electrode area of 700×400 μm in the middle and a 200 μm wide and 2600 μm long counter electrode surrounding it from three sides in a U‐shape. The connection pads (1000×1500 μm) were located at the edge of a sensor‐array chip. Silicon wafer wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 34 publications
0
5
0
Order By: Relevance
“…Potassium hexacyanoferrate is a well-known electroactive probe, and its redox process is frequently used to evaluate electrode performance in voltammetry. ,, Cyclic voltammograms of 10 mmol L –1 potassium hexacyanoferrate­(III) solutions were registered at x ACN varying from 0.0 to 0.65. The experiments performed at a higher content of ACN were not carried out due to the formation of precipitate and phase separation.…”
Section: Resultsmentioning
confidence: 99%
“…Potassium hexacyanoferrate is a well-known electroactive probe, and its redox process is frequently used to evaluate electrode performance in voltammetry. ,, Cyclic voltammograms of 10 mmol L –1 potassium hexacyanoferrate­(III) solutions were registered at x ACN varying from 0.0 to 0.65. The experiments performed at a higher content of ACN were not carried out due to the formation of precipitate and phase separation.…”
Section: Resultsmentioning
confidence: 99%
“…The preparation of the sensor array microchips is described in our previous paper in detail (11). Shortly for fabrication silicon wafers (100 mm diameter and thickness of 500-525 µm) and borosilicate wafers (Pyrex glass with same dimensions as silicon wafers) were used.…”
Section: Methodsmentioning
confidence: 99%
“…The experimental value 0.16 A m −2 mM −1 is in relatively good agreement with the theoretical calculated value. The slope value is greatly overestimated with models using other geometries (10 mV s −1 ): microdisk (5 times), microband (50 times), and infinite plane (6 times) and therefore these models cannot be used (11).…”
Section: Electrochemical Experimentsmentioning
confidence: 99%
See 2 more Smart Citations