2012
DOI: 10.1016/j.chemgeo.2012.08.027
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical sensing of volcanic gases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(37 citation statements)
references
References 47 publications
0
37
0
Order By: Relevance
“…The 1 Hz measurements are then averaged over a user-defined interval (1 min in the present study) and transmitted to a remote server where data are stored in a MySQL database and visualized in real time. Flags were set to mark the first 4 h after a node was turned on to indicate a sensor warmup period (Roberts et al, 2012;Smith et al, 2017). In addition, flags are set whenever the ADC or RHT sensor reported a failure.…”
Section: Sensor Node Designmentioning
confidence: 99%
“…The 1 Hz measurements are then averaged over a user-defined interval (1 min in the present study) and transmitted to a remote server where data are stored in a MySQL database and visualized in real time. Flags were set to mark the first 4 h after a node was turned on to indicate a sensor warmup period (Roberts et al, 2012;Smith et al, 2017). In addition, flags are set whenever the ADC or RHT sensor reported a failure.…”
Section: Sensor Node Designmentioning
confidence: 99%
“…Etna plume HCl by electrochemical sensor builds on the prototype of Roberts et al (2012). Here, the improved HCl electrochemical sensor (HCl-A1) exhibits a more stable sensor baseline (Fig.…”
Section: Analysis Of Hcl/so 2 In Mt Etna Crater's Emissionsmentioning
confidence: 99%
“…In this context, Multi-Gas instruments containing small sensors (Shinohara 2005;Shinohara and Witter 2005;Aiuppa et al 2005b;Roberts et al 2012) offer the capability for real-time in situ monitoring of several volcanic gases (typically SO 2 and H 2 S by electrochemical sensor, CO 2 and H 2 O by infra-red sensor), including long-term installations with data telemetry, e.g. at Italian volcanoes Mt.…”
Section: Volcanic Gas Measurements and Multi-gasmentioning
confidence: 99%
See 1 more Smart Citation
“…This can lead to errors and uncertainties in the derived gas ratios if not properly taken into account (Roberts et al, 2014). Also, the electrochemical sensors have cross-sensitivities to other gases -oftentimes gases found in great abundance in volcanic plumes (Roberts et al, 2012). A typical electrochemical H 2 S sensor, for example, can have a cross-sensitivity to SO 2 of up to 20 % (Roberts et al, 2014).…”
Section: F Vita Et Al: Development Of a Portable Active Lp-doasmentioning
confidence: 99%