2002
DOI: 10.1021/ac0202278
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
336
0
3

Year Published

2005
2005
2019
2019

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 561 publications
(339 citation statements)
references
References 241 publications
0
336
0
3
Order By: Relevance
“…Over the years, covalent attachment of sensing components emerged as an attractive solution for the problem of their insufficient retention. 23 We have earlier demonstrated that modified SP can be attached to activated polymethylmethacryllic (PMMA)-based surface binding sites with full preservation of the ability of SP to switch between the active and passive form and detection of Co 2+ while in active form. 16 In light of our attempts for simplification of sensing platform, it is important to note that the switching can be achieved using simple LEDs.…”
Section: Discussionmentioning
confidence: 99%
“…Over the years, covalent attachment of sensing components emerged as an attractive solution for the problem of their insufficient retention. 23 We have earlier demonstrated that modified SP can be attached to activated polymethylmethacryllic (PMMA)-based surface binding sites with full preservation of the ability of SP to switch between the active and passive form and detection of Co 2+ while in active form. 16 In light of our attempts for simplification of sensing platform, it is important to note that the switching can be achieved using simple LEDs.…”
Section: Discussionmentioning
confidence: 99%
“…The measurement of potential value of the system is conducted on zero current condition. 1,2 This method can measure very low ionic concentrations that is in 10 −10 M or in parts per trillion (ppt). 3 According to International Union of Pure and Applied Chemistry (IUPAC), potentiometric analysis measures the potential difference that occurs between the working and reference electrodes, which is directly proportional to the logarithm of the concentration of ions.…”
Section: Introductionmentioning
confidence: 99%
“…1 The ISE responds to the activity (concentration) of the sensed ion in the tested solution. 2,3 The potentiometric liquid membrane for the ISE includes an ionophore that captures a specific ion more tightly than other ions. Aza-crown ethers as ionophores of ISEs have attracted much attention due to their facile design as analytical reagents for the target ions.…”
Section: Introductionmentioning
confidence: 99%