2013
DOI: 10.1007/s11164-013-1055-x
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical studies of mild steel corrosion inhibition in sulfuric acid chloride by aniline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(9 citation statements)
references
References 53 publications
0
9
0
Order By: Relevance
“…The addition of 4-8 wt% of thiourea in acidic zinc electroplating bath reduced the corrosion rate in sea water by 30%. 18 Thiourea would perform as an inhibition agent to increase the overpotential of zinc dissolution/deposition during the ZAB discharge-charge cycles, thus leading to fine structures of zinc deposits. In contrast, the zinc dendrite growth in alkaline electrolyte is so significant that it will penetrate to the air cathode and short the battery cell.…”
Section: Resultsmentioning
confidence: 99%
“…The addition of 4-8 wt% of thiourea in acidic zinc electroplating bath reduced the corrosion rate in sea water by 30%. 18 Thiourea would perform as an inhibition agent to increase the overpotential of zinc dissolution/deposition during the ZAB discharge-charge cycles, thus leading to fine structures of zinc deposits. In contrast, the zinc dendrite growth in alkaline electrolyte is so significant that it will penetrate to the air cathode and short the battery cell.…”
Section: Resultsmentioning
confidence: 99%
“…According to Ref. , this may be traceable to the nature and tenacity of the passive film produced by Zn‐TiO 2 ‐1.0A on the surface of the coated steel. It is essential to note that improvement in potential was discovered appreciably for all the coatings, which could be attributed to the barrier effect of the film precipitated on the surface of the steel substrate, thereby shielded it from the corrosive environment .…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the shapes of polarization curves are parallel with the increase of concentration for the two investigated inhibitors, indicating that the action mechanism is same under different concentrations of inhibitors. Generally, it is considered as a cathodic inhibitor when the potential change exceeds 85 mV, while it is a mixed inhibitor when the potential change is less than 85 mV [25,26]. From Table 2, the changed values of E corr for the two inhibitors are less than 85 mV, suggesting that AIA and NIA are mixed corrosion inhibitors.…”
Section: Resultsmentioning
confidence: 99%