2013
DOI: 10.1109/tdei.2013.6508738
|View full text |Cite
|
Sign up to set email alerts
|

Electrode design improvement for impedance evaluation of biological cell culture under variable frequency low intensity sinusoidal electric field

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…These dimensions have been selected based on the optimized geometry in the ECIS platform. 18 Finally, a polydimethylsiloxane (PDMS) well is fabricated by soft lithography technique and composed over the porous area for containing the cell suspension.…”
Section: A Ps Formation and Surface Modificationmentioning
confidence: 99%
See 1 more Smart Citation
“…These dimensions have been selected based on the optimized geometry in the ECIS platform. 18 Finally, a polydimethylsiloxane (PDMS) well is fabricated by soft lithography technique and composed over the porous area for containing the cell suspension.…”
Section: A Ps Formation and Surface Modificationmentioning
confidence: 99%
“…Electrical measurement by impedance spectroscopy not only monitors cellular adhesion, spreading, and proliferation but also quantitatively estimates the average values of cell-cell junction resistance and cell membrane-substrate distance, along with their fluctuations due to micromotion. 18,19 However, these measurements have been carried out using electric cell substrate impedance sensing (ECIS) wells with patterned gold electrodes on plastic substrates whose topographies are not found in nature. 20 Hence, to mimic in vivo cellular responses, it is more appropriate to study the intra-and extracellular mechanisms on porous topographies.…”
Section: Introductionmentioning
confidence: 99%
“…The working electrode (WE) is around 250 µm in diameter and its spacing with the counter electrode (CE) is around 300 µm. These dimensions have been selected based on the optimized geometry in the ECIS platform reported earlier [21]. W Finally, a polydimethylsiloxane (PDMS) well has been fabricated by soft lithography technique and attached over the porous area of the sensor.…”
Section: A Sensor Fabricationmentioning
confidence: 99%
“…Solving the different balances in the crystallite region inside the WE [21], the potential (V 1 ) and current distribution (I c1 ) is given by equation 1:…”
Section: Analytical Model For Impedance Calculationmentioning
confidence: 99%
See 1 more Smart Citation