Electroless Deposition of Ni-P on Poly (ether ether ketone)/Multi-Walled Carbon Nanotubes Composite and Improvement of the Electrical Conductivity in Direction of Thickness

Abstract: Electroless deposition of Ni-P coating on Poly (ether ether ketone) (PEEK) and PEEK/multi-walled carbon nanotubes (MWCNTs) composites was reported. A micro/nano hierarchical porous network was formed on the surface after swelling and sonicating. This structure led to a hydrophobic surface with a water contact angle about 125°. However, the surface area and roughness were improved and some MWCNTs were exposed on the wall of porous network for PEEK/MWCNTs composites. When the NaBH4 absorbed samples were put into… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 28 publications
0
1
0
Order By: Relevance
“…Additionally, a DPO test was performed showing the predominance of adhesive failure between the Ni-P coating and the epoxy adhesive, although the black parts indicate a failure at the Ni-P/PHNBR interface, as shown in Figure 9. The mean adhesive strength was 1.0 ± 0.5 MPa which is not far from the values reported for electroless plating on other polymeric substrates: 1.65-2.09 MPa for electroless copper plating on acrylonitrile butadiene styrene (ABS) resin [42] and 2.5-4.5 MPa for metallized PEEK via ENP [43]. The adhesion and structural integrity of the Ni-P film plated on HNBR were evaluated under strong deformation conditions by using an indirect method, namely by measuring the electrical resistance while bending the samples repetitively at 90 • , as shown in Figure 10.…”
Section: Ni-p Agmentioning
confidence: 54%
“…Additionally, a DPO test was performed showing the predominance of adhesive failure between the Ni-P coating and the epoxy adhesive, although the black parts indicate a failure at the Ni-P/PHNBR interface, as shown in Figure 9. The mean adhesive strength was 1.0 ± 0.5 MPa which is not far from the values reported for electroless plating on other polymeric substrates: 1.65-2.09 MPa for electroless copper plating on acrylonitrile butadiene styrene (ABS) resin [42] and 2.5-4.5 MPa for metallized PEEK via ENP [43]. The adhesion and structural integrity of the Ni-P film plated on HNBR were evaluated under strong deformation conditions by using an indirect method, namely by measuring the electrical resistance while bending the samples repetitively at 90 • , as shown in Figure 10.…”
Section: Ni-p Agmentioning
confidence: 54%