2004
DOI: 10.2528/pier03080801
|View full text |Cite
|
Sign up to set email alerts
|

Electromagnetic Analysis of a Non-Invasive 3d Passive Microwave Imaging System

Abstract: Abstract-A technique based on the Green's function theory is used in the present research in order to study theoretically the focusing properties of a constructed 3D non-invasive microwave imaging system, consisting of an ellipsoidal conductive cavity and a radiometric receiver. A double layered spherical human head model is placed on one focal point of the elliptical reflector, while the receiving antenna is placed on the other focus. Making use of the reciprocity theorem, the equivalent problem of the coupli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
48
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 30 publications
(53 citation statements)
references
References 13 publications
5
48
0
Order By: Relevance
“…Water phantom and animal experiments demonstrate that the voltage output from the system is linearly correlated with the actual temperature of the subjects of interest, a fact that is expected when the conductivity of the media under measurement remains unchanged [2][3][4][5]7]. Experimental data from cylindrical shaped saline or de-ionized water filled tank phantoms, in which saline solutions of different concentrations were infused, provide promising results concerning the systems capability of detecting conductivity variations in phantoms at 3.5 GHz [6].…”
Section: System Overviewmentioning
confidence: 99%
See 3 more Smart Citations
“…Water phantom and animal experiments demonstrate that the voltage output from the system is linearly correlated with the actual temperature of the subjects of interest, a fact that is expected when the conductivity of the media under measurement remains unchanged [2][3][4][5]7]. Experimental data from cylindrical shaped saline or de-ionized water filled tank phantoms, in which saline solutions of different concentrations were infused, provide promising results concerning the systems capability of detecting conductivity variations in phantoms at 3.5 GHz [6].…”
Section: System Overviewmentioning
confidence: 99%
“…According to previous experimental results the system shows the ability of measuring temperature and conductivity variations in phantoms and biological tissues [2][3][4][5][6][7]. Water phantom and animal experiments demonstrate that the voltage output from the system is linearly correlated with the actual temperature of the subjects of interest, a fact that is expected when the conductivity of the media under measurement remains unchanged [2][3][4][5]7].…”
Section: System Overviewmentioning
confidence: 99%
See 2 more Smart Citations
“…Development of non-invasive imaging has gained traction over the years due to its important role in basic research and clinical diagnosis [1][2][3]. Optical imaging methods using near infrared light are considered harmless.…”
Section: Introductionmentioning
confidence: 99%