2012
DOI: 10.1016/j.chroma.2011.08.058
|View full text |Cite
|
Sign up to set email alerts
|

Electromembrane extraction of stimulating drugs from undiluted whole blood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
36
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 63 publications
(37 citation statements)
references
References 47 publications
1
36
0
Order By: Relevance
“…During the elution process, because the adsorption of reversed-phase stationary phase for the enriched ionic complex is less than the adsorption of the eluent for the ionic complex, the enriched ionic complex is eluted down [27,28]. In this experiment, when the pure organic solvent was used as an eluent, the eluting efficiency of the eluent declines with the enhancement of the polarity of the eluent (methanol \ ethanol \ acetonitrile \ acetone \ tetrahydrofuran).…”
Section: Mechanism Of Eluting Processmentioning
confidence: 97%
“…During the elution process, because the adsorption of reversed-phase stationary phase for the enriched ionic complex is less than the adsorption of the eluent for the ionic complex, the enriched ionic complex is eluted down [27,28]. In this experiment, when the pure organic solvent was used as an eluent, the eluting efficiency of the eluent declines with the enhancement of the polarity of the eluent (methanol \ ethanol \ acetonitrile \ acetone \ tetrahydrofuran).…”
Section: Mechanism Of Eluting Processmentioning
confidence: 97%
“…Over the past decades, minimization of organic solvents consumed in the sample preparation has become a major trend. Therefore, several eco-friendly sample pretreatment techniques such as liquid phase microextraction [12][13][14][15][16], electromembrane extraction [17,18], supercritical fluid extraction [19], stir bar sorptive extraction [20] and solidphase microextraction (SPME) [21] were employed as alternatives for the extraction of amphetamines from biological matrices.…”
Section: Introductionmentioning
confidence: 99%
“…Due to use of a little amount of organic solvent (microliter), EME is environmentally friendly extraction technique . Up to date, EME has been used for the extraction of drugs , environmental pollutants , metals and ions , amino acids and peptides from different matrices. Several analytical methods such as HPLC , UPLC , LC‐MS/MS , CZE and RIA were reported for determination of some Gn‐RH agonists in different sample matrices.…”
Section: Introductionmentioning
confidence: 99%