Electromembrane extraction of zwitterionic compounds as acid or base: Comparison of extraction behavior at acidic and basic pHs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
11
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
5

Relationship

5
0

Authors

Journals

citations
Cited by 29 publications
(14 citation statements)
references
References 29 publications
3
11
0
Order By: Relevance
“…The obtained results showed that aliphatic alcohols were suitable organic solvents (as SLM) for the extraction of inorganic anions as also demonstrated in earlier works . Also, it was mentioned that acidic compounds were extracted using aliphatic alcohols (especially with 1‐octanol) . Thus, all of these results verify that aliphatic alcohols can be applied as the SLM solvents for the extraction of compounds (organic or inorganic) with negative charge/charges.…”
Section: Resultssupporting
confidence: 80%
See 1 more Smart Citation
“…The obtained results showed that aliphatic alcohols were suitable organic solvents (as SLM) for the extraction of inorganic anions as also demonstrated in earlier works . Also, it was mentioned that acidic compounds were extracted using aliphatic alcohols (especially with 1‐octanol) . Thus, all of these results verify that aliphatic alcohols can be applied as the SLM solvents for the extraction of compounds (organic or inorganic) with negative charge/charges.…”
Section: Resultssupporting
confidence: 80%
“…In the EME procedure, the pH in both sides of the SLM must be adjusted to the optimized values in order to ensure sufficient ionization of the analytes in the sample and acceptor solutions . However, inorganic anions are most often in anionic form across the whole range of pH values.…”
Section: Resultsmentioning
confidence: 99%
“…The equipment used for the EME procedure was the same as that described in previous work . Platinum wires with a diameter of 0.25 mm were used as electrodes in the donor and acceptor solutions, and were connected to the power supply.…”
Section: Methodsmentioning
confidence: 99%
“…Also, the pH values of sample and acceptor solutions determine the ion balance (defined as the ratio of the sum of ions in the donor solution divided by the sum of ions in the acceptor solution) across the system. It has been shown that ion balance impresses the flux through the membrane, so that the flux may decrease by increasing this ratio, as described by the corresponding theoretical model .…”
Section: Introductionmentioning
confidence: 98%