1996
DOI: 10.1016/0021-8502(96)86892-3
|View full text |Cite
|
Sign up to set email alerts
|

Electrospraying of conducting liquids for monodisperse aerosol generation in the 4 nm to 1.8 μm diameter range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

7
145
0

Year Published

2006
2006
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 103 publications
(152 citation statements)
references
References 0 publications
7
145
0
Order By: Relevance
“…These results suggest that the jet can maintain its integrity up to the current transfer region only for moderate values of € Q/Q e , which is in agreement with the observations of Fernandez de la Mora et al (1990) and Chen, Pui & Kaufman (1995) and with the conclusions of Lopez-Herrera & Gafian-Calvo (2004). However, the growth rate can be reduced by the stabilizing effect of jet stretching, which has not been accounted for here.…”
supporting
confidence: 92%
See 1 more Smart Citation
“…These results suggest that the jet can maintain its integrity up to the current transfer region only for moderate values of € Q/Q e , which is in agreement with the observations of Fernandez de la Mora et al (1990) and Chen, Pui & Kaufman (1995) and with the conclusions of Lopez-Herrera & Gafian-Calvo (2004). However, the growth rate can be reduced by the stabilizing effect of jet stretching, which has not been accounted for here.…”
supporting
confidence: 92%
“…The Rayleigh capillary instability may cause the breakup of the jet in this region, and the diameter of the droplets would then be of the order of the local radius of the jet, in agreement with the cubic root law (1.4b) of Fernandez de la Mora & Loscertales (1994) except for the function g(e). The charge of the droplets would be of the order of the Rayleigh limit charge, also in agreement with experimental results Chen et al 1995;de Juan & Fernandez de la Mora 1997;Ganan-Calvo et al 1997). The viscosity of the liquid will affect the breakup of the jet and the size of the droplets when pyrj/x 2 ~ €~5 /3 Re 2 (Q/Q e ) 1/3 is not large.…”
supporting
confidence: 85%
“…Further, it has been experimentally observed that the residue particle size is strongly correlated with the capillary flow rate [28] …”
Section: Neutralization Chambermentioning
confidence: 99%
“…Also, because the ES community (especially mass spectrometry) uses different capillary diameters and hence the flow volume [28,53,98] can vary significantly time was replaced with equivalent capillary volume, which is defined by the product of time with capillary flow rate, and divided by the total volume within the capillary. In this regard, the mass-spectrometry community typically uses different passivations on silica surfaces to reduce protein adsorption which concomitantly reduces the long waiting times before protein breakthrough [99].…”
Section: Sample Preparationmentioning
confidence: 99%
“…In addition, the droplet size can be tightly controlled by adjusting operating parameters such as liquid flow rate and electrical conductivity. While operating in the so-called cone-jet mode (Cloupeau and Prunet-Foch 1989), the ES exhibits an unmatched ability to produce an aerosol containing quasi-monodisperse particles, especially in the nanometer size range (Fernandez de la Mora et al 1990;Tang and Gomez 1994;Chen et al 1995). However, the size of the droplets generated is monotonically dependent on the flow rate used to establish the cone-jet (Rosell-Llompart and Fernandez de la Mora 1994; Tang and Gomez 1994;Chen and Pui 1997).…”
Section: Introductionmentioning
confidence: 99%