1996
DOI: 10.1021/ac950892z
|View full text |Cite
|
Sign up to set email alerts
|

Eluent Jet Interface for Combining Capillary Liquid Flows with Electron Impact Mass Spectrometry

Abstract: A new interface based on an eluent jet in combination with a conventional gas chromatography momentum separator for use with electron impact mass spectrometry is described. The formation of the eluent jet is based on radio frequency inductive heating. The aerosol formation in the interface is discussed in relation to commercial particle beam (PB) interfaces. The interface is tested in combination with electron impact mass spectrometry using flow injection analysis at flow rates in the range of 5-15 µL/ min com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
14
0

Year Published

1997
1997
2005
2005

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(14 citation statements)
references
References 26 publications
0
14
0
Order By: Relevance
“…This appraisal should help to stimulate ongoing attempts to improve the PB interface design and, thus, improve analyte detectability. 41 Spectral information from this study was used in a recently developed automated on-line SPE/LC/PBMS method for the analysis of carbamates and their transformation products in surface water ; the compounds could be identiÐed from their full-scan spectra at lowand sub-kg l~1 levels.2…”
Section: Resultsmentioning
confidence: 99%
“…This appraisal should help to stimulate ongoing attempts to improve the PB interface design and, thus, improve analyte detectability. 41 Spectral information from this study was used in a recently developed automated on-line SPE/LC/PBMS method for the analysis of carbamates and their transformation products in surface water ; the compounds could be identiÐed from their full-scan spectra at lowand sub-kg l~1 levels.2…”
Section: Resultsmentioning
confidence: 99%
“…Although thousands of studies have been published on new and improved API interfaces, only a few authors have contributed to the attempt of efficiently generating EI spectra from a liquid effluent: Kientz et al (1996) were able to generate EI spectra based on an eluent-jet formation by means of inductive heating of the micro-LC effluent, and momentum separation in a jet separator; Dijkstra et al (1998) improved that technique with a particular emphasis on its use under chemical ionization (CI)-MS conditions; and Amirav and Granot (2000) developed a new apparatus to obtain high-quality, library-searchable EI spectra based on supersonic molecular beam mass spectrometry (SMB-MS) approach. That valuable attempt allows conventional mobile phase flow rates and enhances molecular ion response for an improved molecular weight determination.…”
Section: Introductionmentioning
confidence: 99%
“…For example, Kientz (1996) proposed a different approach for generating electron ionization spectra from an HPLC ef¯uent, based on an eluent-jet formation by means of inductive heating of the micro-LC ef¯uent, and momentum separation in a jet separator. Dijkstra (1998) lately improved this technique with a particular emphasis on its use under CI-MS conditions.…”
Section: Introductionmentioning
confidence: 99%