Matrix-dependent signal suppression or enhancement represents a major drawback in quantitative analysis with liquid chromatography coupled to atmospheric pressure ionization mass spectrometry (LC-API-MS). Because matrix effects (ME) might exert a detrimental impact on important method parameters (limit of detection, limit of quantification, linearity, accuracy, and precision), they have to be tested and evaluated during validation procedure. This review gives a detailed description on when these phenomena might be expected, and how they can be evaluated. The major sources of ME are discussed and illustrated with examples from bioanalytical, pharmaceutical, environmental, and food analysis. Because there is no universal solution for ME, the main strategies to overcome these phenomena are described in detail. Special emphasis is devoted to the sample-preparation procedures as well as to the recent improvements on chromatographic and mass spectrometric conditions. An overview of the main calibration techniques to compensate for ME is also presented. All these solutions can be used alone or in combination to retrieve the performance of the LC-MS for a particular matrix-analyte combination.
A major limitation in quantitative analysis with electrospray ionization mass spectrometry (ESI-MS) is represented by the so-called matrix effects in which the matrix coextracted with the analytes can alter the signal response, causing either suppression or enhancement, resulting in poor analytical accuracy, linearity, and reproducibility. In the direct electron ionization liquid chromatography-mass spectrometry (direct-EI LC-MS) interface the ionization process is based on electron impact ionization, and it occurs in the gas phase and is not influenced by coeluted matrix compounds. In this work we quantitatively evaluated matrix effects on enriched environmental and biological samples, with different extraction procedures, using ESI and direct-EI LC-MS. As expected, the samples analyzed with direct-EI were not affected by matrix composition, whereas with ESI we observed either signal suppression or enhancement, depending on the sample nature.
A new LC/MS method for the determination of organophosphorus pesticides in water, based on the use of direct-electron ionization (EI) interface, is presented. Direct-EI is a new device that, in a very simple fashion, couples a nano-HPLC system with a mass spectrometer equipped with electron ionization capability. The nanoscale liquid flow allows for a direct introduction of eluate into the ion source and, after nebulization, for its ionization under typical EI conditions. Library-matchable EI spectra are generated for a choice of full scan or SIM detection of the analytes. In our case, a selection of organophosphorus pesticides, commonly distributed in local sugar beet cultivation, were considered. The new interface permits a very sensitive detection of the analytes in a wide range of linear response (0.09-9 ng). When applied to a real sample, the method allowed detecting four different pesticides at a concentration level of approximately 3 ng x L(-1).
Major progress in interfacing liquid chromatography and electron ionization mass spectrometry is presented. The minimalism of the first prototype, called the Direct-EI interface, has been widely refined, improved, and applied to modern instrumentation. The simple interfacing principle is based on the straight connection between a nanoHPLC system and a mass spectrometer equipped with an EI source forming a solid and reliable unicum resembling the immediacy and straightforwardness of GC/MS. The interface shows a superior performance in the analysis of small-medium molecular weight compounds, especially when compared to its predecessors, and a unique trait that excels particularly in the following aspects: (1) It delivers high-quality, fully library matchable mass spectra of most sub-1 kDa molecules amenable by HPLC. (2) It is a chemical ionization free interface (unless operated intentionally) with accurate reproduction of the expected isotope ion abundances. (3) Response is never influenced by matrix components in the sample or in the mobile phase (nonvolatile salts are also well accepted). A deep evaluation of these aspects is presented and discussed in detail. Other characteristics of the interface performance such as limits of detections, range of linear response, and intra- and interday signal stability were also considered. The usefulness of the interface has been tested in a few real-world applications where matrix components played a detrimental role with other LC/MS techniques.
Contamination of water resources by organochlorine pesticides (OCPs) continues to receive widespread attention because of the increasing concern regarding their high persistence and bioaccumulation. These organic pollutants are not amenable by liquid chromatography (LC) coupled to atmospheric pressure ionization-mass spectrometry, which represents the method of choice for the characterization of pesticide residues in water. Gas chromatography-mass spectrometry provides excellent response for OCPs, but it falls short when complex, multiresidue analyses are required. As recently demonstrated, an efficient EI-based LC-MS interface can generate very good spectra for an extremely wide range of small-medium molecular weight molecules of different polarity and can represent a valid tool in solving the analytical challenge of analyzing OCPs by LC-MS. Based on this assumption, we present a new approach for the determination of 12 OCPs in water samples. The method requires a solid-phase extraction preconcentration step followed by nanoscale liquid chromatography coupled to a direct-electron ionization direct interface (Direct-EI). Direct-EI is a miniaturized interface for efficiently coupling a liquid chromatograph with an EI mass spectrometer. The capability to acquire high-quality EI spectra in a wide range of concentrations, and to operate in selected ion monitoring mode during analyses, allowed a precise quantification of the OCPs. Without sample injection enrichment, limits of detection of the method span from 0.044 to 0.33 microg/L, corresponding to an instrumental detection limit of 120-850 pg. In addition, a careful evaluation of the matrix effect showed that the response of the Direct-EI interface was never affected by sample interferences. From our knowledge, the proposed method represents the first application of LC-MS in the analysis of organochlorine pesticides.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.