2019
DOI: 10.1016/j.colcom.2018.11.002
|View full text |Cite
|
Sign up to set email alerts
|

Embedding CuO Nanoparticles in PDMS-SiO2 Coating to Improve Antibacterial Characteristic and Corrosion Resistance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
32
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 80 publications
(34 citation statements)
references
References 46 publications
1
32
0
1
Order By: Relevance
“… 4 ZnO and CuO NPs with less cytotoxicity compared to other MNPs/MONPs such as Ag NPs may be a suitable option to obtain efficient antibacterial formulation. 5 , 6 Ions released by these MONPs are defined as a major antibacterial mechanism which can disrupt the integrity of cell envelope of bacteria. 7 In addition, the antibacterial and biocompatibility of these NPs can be modified by several approaches.…”
Section: Introductionmentioning
confidence: 99%
“… 4 ZnO and CuO NPs with less cytotoxicity compared to other MNPs/MONPs such as Ag NPs may be a suitable option to obtain efficient antibacterial formulation. 5 , 6 Ions released by these MONPs are defined as a major antibacterial mechanism which can disrupt the integrity of cell envelope of bacteria. 7 In addition, the antibacterial and biocompatibility of these NPs can be modified by several approaches.…”
Section: Introductionmentioning
confidence: 99%
“…Among all the SS implants that failed, more than 90% presented corrosion attack [8]. Different physical and chemical techniques have been developed to improve SS resistance to corrosion such as plasma immersion ion implantation and deposition [9], surface modification of biomedical 316 L SS with zirconium carbonitride coatings [10], dip coating [11], electropolishing and acid dipping [12] or sol-gel spin coating [13]. In this study, the electrodeposition of an electro-conductive polymer was chosen to prevent SS corrosion.…”
Section: Introductionmentioning
confidence: 99%
“…Tensile testing allows Young Modulus measurement of PDMS. The Young Modulus can be affected by treatments that may be applied to PDMS, by hardening temperature and time, and by the mixing ratio used to fabricate the PDMS samples [42,96,97]; • X-ray photoelectron spectroscopy (XPS) is a technique based on the photoelectric effect, which allows identification of the elemental composition of the material. This method is useful when it is needed to verify if any changes in surface composition occurred after the PDMS received any treatment [38,39,98];…”
mentioning
confidence: 99%