IEEE Symposium Conference Record Nuclear Science 2004.
DOI: 10.1109/nssmic.2004.1466253
|View full text |Cite
|
Sign up to set email alerts
|

EMCCD-based photon-counting mini gamma camera with a spatial resolution > 100 μm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…The imaging capabilities of such a device have been previously discussed [1,2,[8][9][10]14] and attempts to improve upon the spatial resolution through fitting to the raw data will be made. Automatic scale selection has been shown to fit the purpose required here with simple discrete Gaussian images.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The imaging capabilities of such a device have been previously discussed [1,2,[8][9][10]14] and attempts to improve upon the spatial resolution through fitting to the raw data will be made. Automatic scale selection has been shown to fit the purpose required here with simple discrete Gaussian images.…”
Section: Discussionmentioning
confidence: 99%
“…One method of analysis which is often used in the literature [1,2,14] is to 'smooth' the image. This generally involves convoluting the image with a Gaussian kernel.…”
Section: Smoothingmentioning
confidence: 99%
“…Some of the light produced in the scintillator from the interaction of an incident X-ray photon spreads out radially (to a first approximation) from the point of interaction, despite the columnar structure. Each single X-ray photon therefore produces a spread of light at the detector, spreading over approximately 5 × 5 pixels to 9 × 9 pixels in area, with the peak intensity and the spread dependent on the X-ray energy and the interaction depth in the scintillator (a higher peak intensity and smaller spread would be seen with an X-ray interacting closer to the detector) 8,14,15 .…”
Section: Proof-of-principlementioning
confidence: 99%
“…To extract clusters, we implement similar techniques as those used in image-intensified (Bazooka SPECT) and EMCCD gamma cameras. 1,6,7,9 First, a background image is subtracted and then the frame is thresholded slightly above the noise variance. Next, each frame is searched for contiguous regions of signal above the threshold, which are then identified as individual events.…”
Section: Photon Countingmentioning
confidence: 99%
“…However, if the detector is operated in photon-counting mode, the gamma-ray interaction position can be estimated using either Anger (centroid) estimation or maximumlikelihood position estimation resulting in a substantial improvement in spatial resolution. 2 Due to the low-light-level nature of the scintillation process, CCD-based gamma cameras implement an amplification stage in the CCD via electron multiplying (EMCCDs) [8][9][10] or via an image intensifier prior to the optical path. 1 We have applied ideas and techniques from previous systems to our high-resolution LumiSPECT detector.…”
mentioning
confidence: 99%