1990
DOI: 10.1016/s0890-5096(06)60844-3
|View full text |Cite
|
Sign up to set email alerts
|

End-to-side Aortoprosthetic Anastomoses: Long-term Computed Tomography Assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0
1

Year Published

1992
1992
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(14 citation statements)
references
References 3 publications
0
13
0
1
Order By: Relevance
“…Discontinuity of the anastomosis causes a false PAAA that usually occurs as a result of arterial wall disruption and mechanical stress4,7,9,13-20 rather than because of graft/suture material failure 21. Aorta versus graft compliance/diameter mismatch9,10,13,14 and extreme mechanical stress (greater in end-to-side rather than end-to-end anastomoses) at the suture-line play major pathogenetic roles 4,10,19-24. Hypertension,4,25 atherosclerosis, and previous aortic endarterectomy4 are important in suture-line failure 24.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Discontinuity of the anastomosis causes a false PAAA that usually occurs as a result of arterial wall disruption and mechanical stress4,7,9,13-20 rather than because of graft/suture material failure 21. Aorta versus graft compliance/diameter mismatch9,10,13,14 and extreme mechanical stress (greater in end-to-side rather than end-to-end anastomoses) at the suture-line play major pathogenetic roles 4,10,19-24. Hypertension,4,25 atherosclerosis, and previous aortic endarterectomy4 are important in suture-line failure 24.…”
Section: Discussionmentioning
confidence: 99%
“…Aorta versus graft compliance/diameter mismatch9,10,13,14 and extreme mechanical stress (greater in end-to-side rather than end-to-end anastomoses) at the suture-line play major pathogenetic roles 4,10,19-24. Hypertension,4,25 atherosclerosis, and previous aortic endarterectomy4 are important in suture-line failure 24. Major peri-operative complications, technical errors, recurrent aneurysm and α 1 -antitrypsin deficiency may be associated with an early onset of pseudoaneurysm 9-11…”
Section: Discussionmentioning
confidence: 99%
“…Despite improved surgical techniques and the availability of better graft and suture materials, enhanced patient survival rates and the use of postoperative imaging of patients with aorto-iliac graft have resulted in an increase in the observed incidence of anastomotic aneurysms, varying from 0.2% to 15% (6,7). MULDER et al reported that 44% of patients with untreated anastomotic pseudoaneurysms die of rupture after a mean follow-up of 6 years and postoperative mortality rates of 7.6% have been reported (8).…”
Section: Discussionmentioning
confidence: 99%
“…A melhor forma de controle desta complicação é através de exames de imagem (ultra-sonografia ou angiotomografia), que devem ser realizados nos controles tardios dos pacientes submetidos a enxerto aórtico 16 . Gautier coloca que, frente ao diagnóstico de falso aneurisma envolvendo a artéria femoral, deve-se suspeitar e investigar logo a presença de falso aneurisma aórtico 6 .…”
Section: Discussionunclassified