1982
DOI: 10.1073/pnas.79.1.106
|View full text |Cite
|
Sign up to set email alerts
|

Energy-filtered transmission electron microscopy of ferritin.

Abstract: ASTRACT The focusing properties of a magnetic-sector spectrometer are shown to be suitable for forming high-spatial-resolution, energy-filtered transmission electron microscope.images. Filtered images of ferritin molecules by using electrons scattered from the-characteristic iron M2,3 and carbon K absorption edges clearly distinguish the 75-A iron core and 120-A protein shell. The minimum detectable mass is estimated to be 0.84 x 10-20 g for Fe for an electron dose of'18 C/cm2 and 99% confidence. OP1Viewing sc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

1982
1982
2011
2011

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…De-* To whom correspondence should be addressed. dicated STEM/EELS instruments have analyzed the chemical analytical potentials of this combination in biological and non-biological materials [6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23]27]. The formation of elemental distribution images has been described for both combinations [5,8,13,14,17].…”
Section: Introductionmentioning
confidence: 99%
“…De-* To whom correspondence should be addressed. dicated STEM/EELS instruments have analyzed the chemical analytical potentials of this combination in biological and non-biological materials [6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23]27]. The formation of elemental distribution images has been described for both combinations [5,8,13,14,17].…”
Section: Introductionmentioning
confidence: 99%
“…The first-order aberrations and distortions can be removed by placing several round lenses plus quadrupole lenses [11], or quadrupoles alone [12] [13,14]. Image quality is then limited only by thirdorder aberrations and distortions, and recorded images of 1024 x 1024 pixels are indistinguishable from images recorded by even the most highly corrected 03A9-filters, which employ 4 magnetic sectors and 7 sextupoles [7].…”
mentioning
confidence: 99%
“…As previously shown, this approach may be particularly useful when the uncertainty of analysis is not limited by gain variations ( Wang et al ., 1992 ) and the signal‐to‐background is insufficient for application of the inverse power law models. For the detection of high local concentrations, application of the inverse power law is generally sufficient ( Egerton, 1981; Pun et al ., 1984 ), even for energy‐filtered transmission electron microscopic imaging ( Shuman & Somlyo, 1981, 1982; Kothleitner & Hofer, 1998).…”
Section: Discussionmentioning
confidence: 99%