2014
DOI: 10.1016/j.colsurfb.2014.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Engineering of Δ 9 -tetrahydrocannabinol delivery systems based on surface modified-PLGA nanoplatforms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

6
25
0

Year Published

2016
2016
2025
2025

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 28 publications
(31 citation statements)
references
References 49 publications
6
25
0
Order By: Relevance
“…The choice of the oily phase was based on the solubility of CBD to easily achieve both high encapsulation efficiencies and drug loading. In this regard, whereas the authors that tried to encapsulate distinct cannabinoids in polymer nanoparticles only achieved encapsulation efficiencies around 70% [15,16,21], those studies that utilized lipid-based carriers exhibited values above 90% [17,22]. This comparison has been corroborated by Durán-Lobato et al [23].…”
Section: Resultsmentioning
confidence: 82%
“…The choice of the oily phase was based on the solubility of CBD to easily achieve both high encapsulation efficiencies and drug loading. In this regard, whereas the authors that tried to encapsulate distinct cannabinoids in polymer nanoparticles only achieved encapsulation efficiencies around 70% [15,16,21], those studies that utilized lipid-based carriers exhibited values above 90% [17,22]. This comparison has been corroborated by Durán-Lobato et al [23].…”
Section: Resultsmentioning
confidence: 82%
“…The characteristic bands at 1464 and 1343 cm -1 are associated with the C-H bending. The stretching of C-C-O group appears at 1280 and 1100 cm are attributed to C-O-C group and C-H bond of the methyl group, respectively [32,[34][35][36][37] . The Figure 3c shows the PLGA-PEG spectrum.…”
Section: Resultsmentioning
confidence: 99%
“…Formulation of the γ-Fe 2 O 3 /PLGA (core/shell) particles (of 3:4 γ-Fe 2 O 3 :PLGA weight ratio) was based on the nanoprecipitation solvent evaporation technique, which has been previously used to prepare pure PLGA NPs. 21,75,76 The procedure started with the incorporation of an organic phase containing PLGA and the oleic acid-modified iron oxide nuclei (19 mg, and 14.25 mg in 5 mL of acetone, respectively) to 10 mL of an aqueous solution of PVA (1%, w/v), under sonication (Branson Sonifier 450, Emerson Electric Co., USA). The microtip of the ultrasonic homogenizer was placed into the aqueous phase, leaving 1 cm distance from the bottom of the vial.…”
Section: Introductionmentioning
confidence: 99%