2017
DOI: 10.1016/j.bios.2016.09.076
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced electrocatalytic performance of an ultrafine AuPt nanoalloy framework embedded in graphene towards epinephrine sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 48 publications
(12 citation statements)
references
References 59 publications
1
10
0
1
Order By: Relevance
“…The value of the D/G peaks ratio was found to be 0.12, indicating that such multilayered graphene has crystal structure without significant defects [28]. Meanwhile, the 3D-GF@Au-3, 3D-GF@Au-5, and 3D-GF@Au-7 materials showed that the growth of GR on Au deposited Ni foam can lead to an increase of defect number of the obtained GR structure, as similarly seen in previous reports [2,23,29]. The high value of 2D/G peaks ratio was found around 0.58, 1.24, and 1.43 for the 3D-GF@Au-3, 3D-GF@Au-5, and 3D-GF@Au-7, respectively, corresponding to the high disorder of Figure 1.…”
Section: Resultssupporting
confidence: 83%
See 2 more Smart Citations
“…The value of the D/G peaks ratio was found to be 0.12, indicating that such multilayered graphene has crystal structure without significant defects [28]. Meanwhile, the 3D-GF@Au-3, 3D-GF@Au-5, and 3D-GF@Au-7 materials showed that the growth of GR on Au deposited Ni foam can lead to an increase of defect number of the obtained GR structure, as similarly seen in previous reports [2,23,29]. The high value of 2D/G peaks ratio was found around 0.58, 1.24, and 1.43 for the 3D-GF@Au-3, 3D-GF@Au-5, and 3D-GF@Au-7, respectively, corresponding to the high disorder of Figure 1.…”
Section: Resultssupporting
confidence: 83%
“…2g). Interestingly, the Au4f peaks of Au in such hybrid downshifted to lower binding energy as compared to that of a pure Au sample [29,33], implying high interactions between Au NPs and GF.…”
Section: Resultsmentioning
confidence: 94%
See 1 more Smart Citation
“…It can be clearly observed that the oxidation and reduction currents for H 2 O 2 increased linearly along with the rising scan rate. In addition, there was a clear linear relationship between the redox peak current and the square root of scan rate (v 1/2 ) using the regression equation Ip (µA) = −111.17υ (mV/s) + 147.84 (R 2 = 0.997), indicating a diffusion-controlled process [46]. Other experimental parameters including concentration and deposition volume of PDDA-AuPtAg/RGO and pH were also investigated to determine the optimal sensor response ( Figure S2, S3).…”
Section: Optimization Of the Experimental Variablesmentioning
confidence: 99%
“…Birçok fizyolojik olay vücut sıvısındaki EP düzeyi ile ilişkilidir [5]. Vücuttaki düşük EP seviyeleri ortostatik hipotansiyon ve parkinson hastalığına yol açarken, yüksek EP seviyeleri ise feokromositoma, hipoglisemi, miyokard infarktüsüne yol açabilir [6,7]. Bu nedenle, EP derişiminin farmasötik numuneler ile plazma ve idrar gibi çeşitli biyolojik sıvılarda belirlenmesi farmakolojik araştırmalar, sinir fizyolojisi ve yaşam bilimleri çalışmaları için önemlidir [8].…”
Section: Gi̇ri̇ş (Introduction)unclassified