2015
DOI: 10.1007/s00421-015-3210-0
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced precision of ankle torque measure with an open-unit dynamometer mounted with a 3D force-torque sensor

Abstract: Assessment of plantar-flexion torque should be performed with an open-unit dynamometer mounted with a 3D sensor that is exclusive of accessory muscles but inclusive of all ankle joint movements.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
15
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 36 publications
0
15
0
Order By: Relevance
“…A custom‐designed dynamometer (Simoneau‐Buessinger et al., ; Toumi et al., ) was used to record the isometric net joint torque around the right ankle at 100 Hz.…”
Section: Methodsmentioning
confidence: 99%
“…A custom‐designed dynamometer (Simoneau‐Buessinger et al., ; Toumi et al., ) was used to record the isometric net joint torque around the right ankle at 100 Hz.…”
Section: Methodsmentioning
confidence: 99%
“…An ankle ergometer 'Booted, Open-unit device, Three dimension sensor, Transportable, Ergometer (B.O.T.T.E.)' was used to record isometric torque at the ankle joint in both DF and PF (Toumi et al 2015). The participant was seated with the hip at ~60°, the dominant leg extended straight forward and the ankle joint placed at 0° (the angle between the plantar surface and the leg D r a f t was a right angle).…”
Section: Methodsmentioning
confidence: 99%
“…, practice (familiarization) (Graves et al 1990), temperature (Morrison et al 2004), ventilation (Li and Laskin 2006), prior physical or mental activities (Bishop 2003, Marcora et al 2009, dynamometer (Toumi et al 2015) and instructions…”
mentioning
confidence: 99%
“…In this manner, torques/forces generated in other parts of the body can contaminate the examined joint torque output. To achieve a direct measure of the contribution of body adjustments to net unilateral and bilateral torque outputs, a customized isometric plantar-flexion (PF) dynamometer was designed [ 25 ]. This innovative ‘Booted, Open-Unit, Three dimension, Transportable, Ergometer’ (B.O.T.T.E.)…”
Section: Introductionmentioning
confidence: 99%
“…The force-torque sensor is situated under a plate on which is placed the sole of the foot. Please see [ 25 ] for more details. The individual in this picture has given written informed consent (as outlined in PLOS consent form) to publish this image.…”
Section: Introductionmentioning
confidence: 99%