2020
DOI: 10.1016/j.snb.2020.127899
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced selectivity and stability of ruthenium purple-modified carbon fiber microelectrodes for detection of hydrogen peroxide in brain tissue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 63 publications
0
4
0
Order By: Relevance
“…Indeed, PB remains a good option for the development of a disposable glucose sensor but its limitation in long contact with H 2 O 2 is not applicable for one-use sensor. Another strategy was recently reported in the literature to lower the detection potentials of H 2 O 2, is to use Ruthenium Purple (RP) as an alternative to the PB material that seems to present better stability over time [129][130][131].…”
Section: Electrochemical Enzymatic Glucose Sensormentioning
confidence: 99%
“…Indeed, PB remains a good option for the development of a disposable glucose sensor but its limitation in long contact with H 2 O 2 is not applicable for one-use sensor. Another strategy was recently reported in the literature to lower the detection potentials of H 2 O 2, is to use Ruthenium Purple (RP) as an alternative to the PB material that seems to present better stability over time [129][130][131].…”
Section: Electrochemical Enzymatic Glucose Sensormentioning
confidence: 99%
“…It allows for a short-term accurate and selective evaluation of a low detection limit on low-cost instrumentation. Moreover, it is one of the most versatile methods because it holds a wide dynamic span, simple instrumentation, and easy miniaturisation, becoming suitable for quantifying changes in H 2 O 2 levels in vivo in the brain [ 42 ]. Furthermore, electrochemical technology based on the catalytic activity allows for an H 2 O 2 detection method of simple, fast, and cost-effective operation [ 43 ] once H 2 O 2 is an electroactive molecule that can be oxidised or reduced on the surface of a solid electrode.…”
Section: Hydrogen Peroxide Electrochemical Detectionmentioning
confidence: 99%
“…According to the previous literature, 34 the construction of the RP film was prepared by electrodeposition in a brilliant purple opaque RP dilute colloidal suspension with cyclic voltammetry scanning. The RP dilute colloidal suspension was prepared as follows.…”
Section: ■ Introductionmentioning
confidence: 99%