“…Each sample was soaked in a test tube with 50 ml phosphate buffer solution (pH 7.4) and maintained in an incubator at 378C. After 0, 2,4,5,6,7,8,12, and 24 weeks of incubation, the respective samples (n 5 5 for each incubation period) were retrieved and subjected to a mechanical test using a testing machine (AGS-J; Simadzu, Kyoto, Japan) at a crosshead speed of 50 mm min 21 . The tensile strengths of the samples were determined from the measured maximum loads.…”