2021
DOI: 10.1016/j.trac.2020.116146
|View full text |Cite
|
Sign up to set email alerts
|

Environmental analysis of polar and non-polar Polycyclic Aromatic Compounds in airborne particulate matter, settled dust and soot: Part II: Instrumental analysis and occurrence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 141 publications
(430 reference statements)
0
13
0
Order By: Relevance
“…According to reports, a programmable temperature vaporizer (PTV) enables the injection of larger volumes when the expected levels are very low, and protects thermolabile compounds by progressively heating and vaporizing them. 119,120 Compared with traditional GC method, the recovery of GC-MS with PTV and an automatic sampler was signicantly improved; this was due to the reduced analyte loss during the sample preparation step. 121…”
Section: Gas Chromatography-mass Spectrometry (Gc-ms)mentioning
confidence: 99%
See 2 more Smart Citations
“…According to reports, a programmable temperature vaporizer (PTV) enables the injection of larger volumes when the expected levels are very low, and protects thermolabile compounds by progressively heating and vaporizing them. 119,120 Compared with traditional GC method, the recovery of GC-MS with PTV and an automatic sampler was signicantly improved; this was due to the reduced analyte loss during the sample preparation step. 121…”
Section: Gas Chromatography-mass Spectrometry (Gc-ms)mentioning
confidence: 99%
“…The PID is suitable for volatile and semi-volatile organic compounds with ionization energies lower than the energy of emitted photons (from 8 to 12 eV). 100 A method based on headspace sampling, and integrated with a portable GC with PID was proposed for the rapid determination of BTEX in soil by Zhou et al 101 This method was suitable for the rapid determination of BTEX in soil on site. 102 Pascale et al 103 established a simple, low-cost, and accurate new method to quantify BTEX based on static headspace extraction-GC-BID.…”
Section: Analysis Techniques For Btex and Pahs In Soilmentioning
confidence: 99%
See 1 more Smart Citation
“…In this work, a fast and green extraction method (ultrasonic-assisted extraction) in combination with silica gel solid phase extraction clean-up of PAHs in the particulate matter samples was introduced. A capillary gas chromatography coupled with electron impact ionization tandem mass spectrometry (GC-EI-MS/MS) was used for detected and quantified of PAHs in particulate matter (PM2.5 and PM10) samples [25,26]. GC-EI-MS/MS was used for this study because of the sensitivity and selectivity.…”
Section: Introductionmentioning
confidence: 99%
“…transitions with no mass loss between MS 1 and MS 2 . 4,5 It was first presented in 2014 by Shang et al 5 They described the use of this monitoring mode for the particular case of PAHs which are "difficult-to-fragment" compounds.…”
mentioning