2023
DOI: 10.1016/j.aca.2022.340700
|View full text |Cite
|
Sign up to set email alerts
|

Environmental iodine speciation quantification in seawater and snow using ion exchange chromatography and UV spectrophotometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 78 publications
0
3
0
Order By: Relevance
“…However, DOI concentrations in seawater are generally much lower than iodate, and typically range from 10 to 40 nmol L -1 (Wong and Cheng, 1998;Truesdale et al, 2001). We checked the DOI levels in samples collected at three depths in Bedford Basin in both November 2022 and April 2023, using the three-step procedure of Jones et al (2023) which involves addition of Ca(ClO) 2 , Na 2 SO 3 and NH 2 OH-HCl. These samples covered seasons with both high (April 2023) and low (November 2022) oxygen concentrations.…”
Section: Analytical Methods For Iodine Analysismentioning
confidence: 99%
“…However, DOI concentrations in seawater are generally much lower than iodate, and typically range from 10 to 40 nmol L -1 (Wong and Cheng, 1998;Truesdale et al, 2001). We checked the DOI levels in samples collected at three depths in Bedford Basin in both November 2022 and April 2023, using the three-step procedure of Jones et al (2023) which involves addition of Ca(ClO) 2 , Na 2 SO 3 and NH 2 OH-HCl. These samples covered seasons with both high (April 2023) and low (November 2022) oxygen concentrations.…”
Section: Analytical Methods For Iodine Analysismentioning
confidence: 99%
“…Importantly, we acknowledge that the spectrophotometric IO 3 measurement is highly prone to interferences (Truesdale, 1978;Luther et al, 1988). Seawater background measurements at 350 nm have the potential to correct these interferences (Hepach et al, 2020;Jones et al, 2023). Note that the controls with addition of SOD and MnCl 2 (meant to test the potential to stop Ioxidation via scrubbing of superoxide or added preferred electron donor) were only relevant if Ioxidation was observed in other controls, so are not considered further.…”
Section: Iodine Measurements From Incubationsmentioning
confidence: 99%
“…Iodide concentrations in the reservoir and the waste stream were directly quantified using UV-vis spectrophotometry at 226 nM following ion exchange chromatography (IC) (Jones et al, 2023). The IC used a Dionex IonPac AS23 guard and analytical column (4 x 250 mm), with a mobile phase eluent of 0.4 M NaCl flowing at 0.64 ml min −1 .…”
Section: Measurement Of Aqueous Iodidementioning
confidence: 99%