1986
DOI: 10.1080/01483918608076643
|View full text |Cite
|
Sign up to set email alerts
|

Enzyme-Analogue Built Polymers. XIX. Racemic Resolution on Polymers Containing Chiral Cavities

Abstract: With the aid of a chiral template molecule binding groups could be placed in a highly crosslinked polymer in s u c h a way that they are present in a chiral cavity of specific shape in a given stereochemistry. Polymers of this type possessed a high selectivity f o r racemic resolution o f the r a c e m a t e o f the template.I n the batch procedure separation factors CI a s h i g h a s 3.65 were obtained.In chromatography similar to other chromatographic racemic resolutions a s l o w m a s s transfer w a s obs… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

1986
1986
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 76 publications
(17 citation statements)
references
References 33 publications
0
17
0
Order By: Relevance
“…After removing the template molecule, a chiral imprinted cavity remains, which shows high stereoselectivity to the template molecule or closely related molecules. This principle was introduced by Wulff's group [173,174]. Whereas Wulff used a covalent attachment technique based on the formation of a template-monomer complex through reversible covalent bonding, Mosbach's group [175] developed a non-covalent route making use of hydrogen bonding, electrostatic interactions, hydrophobic interactions, etc.…”
Section: Chiral Imprinted Polymersmentioning
confidence: 99%
“…After removing the template molecule, a chiral imprinted cavity remains, which shows high stereoselectivity to the template molecule or closely related molecules. This principle was introduced by Wulff's group [173,174]. Whereas Wulff used a covalent attachment technique based on the formation of a template-monomer complex through reversible covalent bonding, Mosbach's group [175] developed a non-covalent route making use of hydrogen bonding, electrostatic interactions, hydrophobic interactions, etc.…”
Section: Chiral Imprinted Polymersmentioning
confidence: 99%
“…The high selectivity and low backpressure could be resolution (R ) was calculated according to the obtained using this porogenic mixture. s method proposed by Wulff et al [21]. The number of As shown in Table 2, the ratio of toluene and theoretical plates (N) was calculated by the equation dodecanol also affects the separation performance 2 N 5 16(t /w) , where w is the baseline peak width of through the change in pore structure of the mono-R eluted enantiomers.…”
Section: 4 High-performance Liquid Chromatographymentioning
confidence: 99%
“…Column 250X 4mm filledwith polymerE3asdescribed previously [5] was used throughout this work. The LC experiments were performed with a system consisting of syringe pump (HPP 5001, Laboratorni pristoje Praha), Model 7010 Rheodyne injector, LC column in liquid thermostatic bath, Perkin Elmer LC 85/Autocontrol spectrophotometric detector and SSI back-pressure regulator in the hydraulic line.…”
Section: Methodsmentioning
confidence: 99%