2016
DOI: 10.1080/08998280.2016.11929477
|View full text |Cite
|
Sign up to set email alerts
|

Epidural Analgesia Complicated by Dural Ectasia in the Marfan Syndrome

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…6 Patients with Marfan syndrome also have a predisposition for dural ectasia, which increases the risk of unintentional dural puncture. 7 The evidence regarding the safety of neuraxial anesthetic techniques in patients with multiple sclerosis, particularly subarachnoid blocks, is mixed. 8 However, a survey among anesthesiologists in the United Kingdom found that 98% would perform a neuraxial technique for cesarean delivery.…”
Section: Discussionmentioning
confidence: 99%
“…6 Patients with Marfan syndrome also have a predisposition for dural ectasia, which increases the risk of unintentional dural puncture. 7 The evidence regarding the safety of neuraxial anesthetic techniques in patients with multiple sclerosis, particularly subarachnoid blocks, is mixed. 8 However, a survey among anesthesiologists in the United Kingdom found that 98% would perform a neuraxial technique for cesarean delivery.…”
Section: Discussionmentioning
confidence: 99%
“…69 Administering epidural anesthesia can be complicated by lumbosacral dural ectasia. 70 Whether this becomes more of a problem as older people with MFS require more surgical procedures is not clear.…”
Section: Nervous Systemmentioning
confidence: 99%
“…When the patient wakes up after anesthesia, the relevant nurse should carefully check whether the related nerve function of the patient is normal, observe the related lying posture, at the same time, move the left and right limbs of the patient, observe whether there is hemiplegia, raise the lower limbs of the patient up and down, first close the eyes of the patient from the paralyzed side, observe the response of light stimulation, and use needle light stimulation or cotton swab friction to stimulate the left and right In addition, the nursing staff should also pay attention to the patient's self-feeling. When the patient complains that the lower limbs cannot move normally, the nursing staff should check the patient's relevant situation and inform the doctor in time [10].…”
Section: Microsurgical Nursing Of Dural Arteriovenous Fistulamentioning
confidence: 99%