2014
DOI: 10.5370/kiee.2014.63.6.780
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings

Abstract: -To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 6 publications
0
1
0
Order By: Relevance
“…Many electrical diagnostic tests have been performed to evaluate the health of insulation systems for rotating machine stator windings. In general, Insulation Resistance(IR), Polarization Index(PI), Dissipation Factor(DF), AC current test and PD test have been conducted and analyzed to assess the soundness of insulation systems as had been shown (Kim, H. D. (2014), Kim, H. D., Kong, T. S., Ju, Y.H., & Kim, B. H. (2011), Kim, H. D., & Kong, T. S. (2012), Kim, H. D., & Kong, T. S. (2014)). Also, it is well known that the O3 is produced when the electric discharge occurs in air and studies are still going on the correlations between PD and O3 emission as works in this topic (Lépine, L., Lessard-Déziel, D., Bélec, M., Guddemi, C., & Nguyen, D.N.…”
Section: Introductionmentioning
confidence: 99%
“…Many electrical diagnostic tests have been performed to evaluate the health of insulation systems for rotating machine stator windings. In general, Insulation Resistance(IR), Polarization Index(PI), Dissipation Factor(DF), AC current test and PD test have been conducted and analyzed to assess the soundness of insulation systems as had been shown (Kim, H. D. (2014), Kim, H. D., Kong, T. S., Ju, Y.H., & Kim, B. H. (2011), Kim, H. D., & Kong, T. S. (2012), Kim, H. D., & Kong, T. S. (2014)). Also, it is well known that the O3 is produced when the electric discharge occurs in air and studies are still going on the correlations between PD and O3 emission as works in this topic (Lépine, L., Lessard-Déziel, D., Bélec, M., Guddemi, C., & Nguyen, D.N.…”
Section: Introductionmentioning
confidence: 99%