2003
DOI: 10.1063/1.1627106
|View full text |Cite
|
Sign up to set email alerts
|

European Dissemination of the Ultra-low Temperature Scale, PLTS-2000

Abstract: The first phase of the EU collaborative project on sub-kelvin thermometry, 'ULT Dissemination', is nearing completion, leading to the development of several thermometers and devices, and the instrumentation needed to disseminate the new Provisional Low Temperature Scale, PLTS-2000, to users. Principal among these are a current-sensing noise thermometer (CSNT), a CMN thermometer adapted for industrial use, a Coulomb blockade thermometer, a second-sound acoustic thermometer and a superconductive reference device… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2003
2003
2019
2019

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…The 3 He used in the MCT was purchased from Chemgas Company. The chemical analysis supplied by Chemgas gives 40 ppm of 4 He in 3 He. As previously tested in Ref.…”
Section: Pressure Measurements At the Minimummentioning
confidence: 99%
See 2 more Smart Citations
“…The 3 He used in the MCT was purchased from Chemgas Company. The chemical analysis supplied by Chemgas gives 40 ppm of 4 He in 3 He. As previously tested in Ref.…”
Section: Pressure Measurements At the Minimummentioning
confidence: 99%
“…This research resulted in a common proposal for an analytical relation, P(T), of polynomial form, and for values given for "in-situ" temperature and pressure fixed points (minimum of the melting curve, superfluid and magnetic transition in solid 3 He). At the same time, as partners of two European projects, the "ULTUltra Low Temperature" [1] and the "ULT dissemination" [3], several European metrological laboratories worked together in order to test the MCT in different environments and to compare the temperatures given by the MCT to that obtained in "local scales." In the context of these European projects, several MCTs were studied and built by PTB.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The use of the word almost here should be understood as follows: we also used resistive thermometers (RuO 2 , carbon Speer-type) calibrated against primary devices, and our primary thermometers (which do follow known temperature dependencies) are calibrated at a single point in temperature for practical reasons. Our laboratory has a long history of working for the construction of the ultra-low temperature scale [59]. In our case, the BF cryostat has been equipped with a Magnicon R MFFT noise thermometer and a CMN paramagnetic salt (Cerium Magnesium Nitrate) thermometer.…”
Section: Acknowledgmentsmentioning
confidence: 99%