1984
DOI: 10.1016/0003-2697(84)90095-2
|View full text |Cite
|
Sign up to set email alerts
|

Europium as a label in time-resolved immunofluorometric assays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

3
466
0
5

Year Published

1996
1996
2016
2016

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 829 publications
(480 citation statements)
references
References 24 publications
3
466
0
5
Order By: Relevance
“…Muscle biopsies were obtained from the vastus lateralis muscle under local anaesthesia during both basal and insulin-stimulated states. Plasma glucose and insulin concentrations and specific activity of 3 H 2 O were measured as previously described [17,24,25].…”
Section: Clinical Examination and Muscle Biopsies In Twinsmentioning
confidence: 99%
“…Muscle biopsies were obtained from the vastus lateralis muscle under local anaesthesia during both basal and insulin-stimulated states. Plasma glucose and insulin concentrations and specific activity of 3 H 2 O were measured as previously described [17,24,25].…”
Section: Clinical Examination and Muscle Biopsies In Twinsmentioning
confidence: 99%
“…Using both spectral and temporal discrimination of the luminescent signal from background autofluorescence enables highly sensitive assays, 5,6 such as the Dissociation Enhanced Lanthanide Fluoro Immuno Assay (DELFIA ® ) techniques first commercialized by Wallac ™ , which use a polyaminocarboxylate chelate of Eu(III). 7 However, the DELFIA ® format is heterogeneous and suffers from the limitation that the fluorescent signal cannot be traced until the end of the assay, when the non-fluorescent Ln(III) chelate is converted to a highly fluorescent form by the addition of a sensitizing -diketonate enhancement solution. Hence, the preparation of efficient lanthanide sensitizers which also form very stable complexes in dilute aqueous solution is an active area of research, since they can be utilized directly and/or covalently bound to a particular biomolecule for use in a less expensive and less time consuming homogenous assays formats.…”
Section: Introductionmentioning
confidence: 99%
“…In a blood glucose range of 4 to 10 mmol/l intra-assay coefficient of variation (CV) was 2.0% and interassay CV was 2.2%. Serum insulin concentrations were measured using a two-site, two-step, time-resolved immunofluorometric assay (DELFIA, Turku, Finland) [15]. Cross-reactivities with proinsulin, C-peptide and Des(31,32)-split product in the insulin assay were all less than 0.4%.…”
mentioning
confidence: 99%