2022
DOI: 10.1007/s12652-021-03635-6
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating the robustness of a contact-less mHealth solution for personal and remote monitoring of blood oxygen saturation

Abstract: MHealth technologies play a fundamental role in epidemiological situations such as the ongoing outbreak of COVID-19 because they allow people to self-monitor their health status (e.g. vital parameters) at any time and place, without necessarily having to physically go to a medical clinic. Among vital parameters, special care should be given to monitor blood oxygen saturation (SpO 2 ), whose abnormal values are a warning sign for potential COVID-19 infection. SpO 2 is commonly measured through the pulse oximete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 37 publications
0
7
0
Order By: Relevance
“…In addition, the T&A method may overcome issues caused by movement. Casalino and colleagues [ 37 ] have described a method for measurement of oxygen saturation using rPPG in which 3 ROIs are used for measurement and a fourth to track head movements. We are exploring the impact of movement on rPPG, whether this differs between healthy volunteers and sick patients, and how T&A may address issues caused by movement during the video recording.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, the T&A method may overcome issues caused by movement. Casalino and colleagues [ 37 ] have described a method for measurement of oxygen saturation using rPPG in which 3 ROIs are used for measurement and a fourth to track head movements. We are exploring the impact of movement on rPPG, whether this differs between healthy volunteers and sick patients, and how T&A may address issues caused by movement during the video recording.…”
Section: Discussionmentioning
confidence: 99%
“…The use of mobile devices for measurement of VSs presents some challenges compared with controlled laboratory scenarios, for example [ 32 ]. To mitigate some of these challenges, we have compared VSs that were measured simultaneously by using SOC methods and Lifelight.…”
Section: Discussionmentioning
confidence: 99%
“…This was obtained by comparing red and blue wavelength bands. However these researches [37], [157], [128], only used a 0.5m range, which is short for a realistic scenario [37], [157], [128].…”
Section: B Remote Spo 2 Measurementmentioning
confidence: 99%