2013
DOI: 10.4236/ijoc.2013.31a002
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a Disc Tube Methodology for Nano- and Ultrafiltration of Natural Dissolved Organic Matter (DOM)

Abstract:

The performance of a disc tube (DT) methodology, originally designed for reverse osmosis (RO) in desalination, and applied here for ultrafiltration (UF) and nanofiltration (NF) of dissolved organic matter (DOM) in a set of fresh (0 ppt), brackish (10 ppt) and saline (30 Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 18 publications
0
8
0
Order By: Relevance
“…In the former, 90 L of Kalix River water was filtered through a 1-kDa Omega polyethersulfone UF membrane (Pall, Germany) according to the set-up of Brockmeyer and Spitzy [35]. The resulting 3.3 L of ultrafiltrate had a DOC concentration of 4408 (±24) μmolC L −1 (recovery rate 40%).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the former, 90 L of Kalix River water was filtered through a 1-kDa Omega polyethersulfone UF membrane (Pall, Germany) according to the set-up of Brockmeyer and Spitzy [35]. The resulting 3.3 L of ultrafiltrate had a DOC concentration of 4408 (±24) μmolC L −1 (recovery rate 40%).…”
Section: Methodsmentioning
confidence: 99%
“…For the experiment, the stored, frozen water was thawed and separate aliquots of the 0.2-μm-filtered tDOM were concentrated by either tangential-flow ultrafiltration or lyophilization [34] . In the former, 90 L of Kalix River water was filtered through a 1-kDa Omega polyethersulfone UF membrane (Pall, Germany) according to the set-up of Brockmeyer and Spitzy [35] . The resulting 3.3 L of ultrafiltrate had a DOC concentration of 4408 (±24) μmolC L −1 (recovery rate 40%).…”
Section: Methodsmentioning
confidence: 99%
“…A 5-point calibration from 0.5 to 5 mg DOC/L was used. The error of measurement is less than 2% (for further analytical details see Brockmeyer and Spitzy, 2013).…”
Section: Docmentioning
confidence: 99%
“…Pore-water samples were taken by rhizons and stored frozen before analyses (see methods in Paul et al, 2018). 18 water samples taken off Namibia were separated into two size classes by ultrafiltration (Brockmeyer and Spitzy, 2013). The size classes 50 kDa-0.7 µm and 1 kDa-0.7 µm were used for AA analyses.…”
Section: Samplingmentioning
confidence: 99%