Evaluation of a tyrosine kinase peptide microarray for tyrosine kinase inhibitor therapy selection in cancer

Abstract: Personalized cancer medicine aims to accurately predict the response of individual patients to targeted therapies, including tyrosine kinase inhibitors (TKIs). Clinical implementation of this concept requires a robust selection tool. Here, using both cancer cell lines and tumor tissue from patients, we evaluated a high-throughput tyrosine kinase peptide substrate array to determine its readiness as a selection tool for TKI therapy. We found linearly increasing phosphorylation signal intensities of peptides rep… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(20 citation statements)
references
References 49 publications
0
19
0
1
Order By: Relevance
“…We therefore aimed to use a kinase activity profiling technique that can be set up under controlled light conditions. In this context, we investigated the kinase activity of HUVECs after treatment with ( E )‐ or ( Z )‐axitinib by using the PamGene Pamstation® and PamChip® technology . The advantage of this method, with regard to photosensitive compounds, is that the experiments can be performed in the dark or under controlled light conditions.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…We therefore aimed to use a kinase activity profiling technique that can be set up under controlled light conditions. In this context, we investigated the kinase activity of HUVECs after treatment with ( E )‐ or ( Z )‐axitinib by using the PamGene Pamstation® and PamChip® technology . The advantage of this method, with regard to photosensitive compounds, is that the experiments can be performed in the dark or under controlled light conditions.…”
Section: Resultsmentioning
confidence: 99%
“…For nonirradiated ( Z )‐axitinib (Figure b), one of three data sets was neglected due to clear outliers. Data analysis was performed as described by Labots et al . For signal evaluation, Bionavigator 6 software (PamGene) was used according to the manufacturer's protocol.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Новым подходом в использовании микрочипов для анализа онкогенных сигнальных путей стала разработка пептидных чипов с субстратной специфичностью к тирозиновым киназам [51,60]. Пептиды на чипе фосфорилируются киназами, присутствующими в аналите, и связываются с флуоресцентно-меченными антителами к фосфотирозину пептидных субстратов.…”
Section: белковые микрочипыunclassified