2015
DOI: 10.2147/nss.s77888
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of an automated single-channel sleep staging algorithm

Abstract: BackgroundWe previously published the performance evaluation of an automated electroencephalography (EEG)-based single-channel sleep–wake detection algorithm called Z-ALG used by the Zmachine® sleep monitoring system. The objective of this paper is to evaluate the performance of a new algorithm called Z-PLUS, which further differentiates sleep as detected by Z-ALG into Light Sleep, Deep Sleep, and Rapid Eye Movement (REM) Sleep, against laboratory polysomnography (PSG) using a consensus of expert visual scorer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
45
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 59 publications
(47 citation statements)
references
References 12 publications
2
45
0
Order By: Relevance
“…Single-channel A1-A2 EEG and automated sleep staging algorithms have recently demonstrated high agreement rate with PSG [6] . Abbreviated montages for sleep staging have also been successful [7] and it is thus conceivable that other single-channel locations could also perform well in algorithmic sleep staging.…”
Section: Discussionmentioning
confidence: 99%
“…Single-channel A1-A2 EEG and automated sleep staging algorithms have recently demonstrated high agreement rate with PSG [6] . Abbreviated montages for sleep staging have also been successful [7] and it is thus conceivable that other single-channel locations could also perform well in algorithmic sleep staging.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, the simpler mechanism of EEG is preferred for the recording of naturalistic sleep, since untrained subjects will be required to use this method in their home. Accordingly, single channel EEG has recently attracted attention ( 19 21 ), although its reliability has not been compared to that of activity-based sleep recorders. To address this question, an EEG recorder Sleep Scope (Sleepwell, Osaka, Japan) was used in the present study, whose prototype device has been previously validated in patients with sleep disorders ( 22 ).…”
Section: Introductionmentioning
confidence: 99%
“…Sleep EEG was collected using a Zmachine Insight+ device (General Sleep Corporation). The Zmachine Insight+ is a single-channel EEG device with accompanying software that provides sleep staging scoring [ 25 , 26 ]. Participants were instructed to place one disposable (ie, one-time use) sensor behind each ear and one on the center of their neck directly prior to getting into bed each evening, and remove the sensors immediately following their final awakening.…”
Section: Methodsmentioning
confidence: 99%
“…This is possible because they obtain EEG data exclusively from outside the hairline (typically from the forehead and sometimes the mastoids), whereas obtaining scalp EEG data from the usual locations employed for in-laboratory studies involves placing electrodes within the hairline, which requires a PSG technologist involvement in order to obtain adequate recordings. Some provide automatic scoring of sleep behaviors and architecture that are user-friendly for patients and providers [ 25 , 26 ]. Among adults, consumer-grade sleep EEG wearables have been used in research and clinic settings [ 27 , 28 ].…”
Section: Introductionmentioning
confidence: 99%