2009
DOI: 10.3168/jds.2008-1795
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of an electronic cowside test to detect subclinical ketosis in dairy cows

Abstract: The objective of this study was to determine the diagnostic performance of an electronic beta-hydroxybutyrate (BHBA) hand-held meter (Precision Xtra) for use in dairy cattle. Specific objectives were to compare the electronic BHBA meter with serum BHBA concentrations determined photometrically and 2 commonly used chemical cowside tests (Ketostix, Ketolac) and to evaluate accuracy in a field study employing 35 investigators. Of the 196 blood samples collected in experiment 1, 17 (8.7%) contained > or =1,200 mic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

20
238
4
9

Year Published

2011
2011
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 251 publications
(271 citation statements)
references
References 9 publications
20
238
4
9
Order By: Relevance
“…The correlation coefficient between the BHBA values obtained from the laboratory method compared to those obtained from the hand-held meter was 0.98 indicating that the hand-held method of testing SCK was as effective and accurate as the laboratory method. The results were in agreement with the findings of other researchers who reported that the coefficient of correlation between the laboratory methods and a hand-held meter in measuring plasma concentration for BHBA varied from 0.92 to 0.97 [2,21,26]. The agreement between the two methods was good since the bias was -0.02 which was lower than 0.036 reported by Voyvoda and Erdogan [2].…”
Section: Discussionsupporting
confidence: 80%
See 4 more Smart Citations
“…The correlation coefficient between the BHBA values obtained from the laboratory method compared to those obtained from the hand-held meter was 0.98 indicating that the hand-held method of testing SCK was as effective and accurate as the laboratory method. The results were in agreement with the findings of other researchers who reported that the coefficient of correlation between the laboratory methods and a hand-held meter in measuring plasma concentration for BHBA varied from 0.92 to 0.97 [2,21,26]. The agreement between the two methods was good since the bias was -0.02 which was lower than 0.036 reported by Voyvoda and Erdogan [2].…”
Section: Discussionsupporting
confidence: 80%
“…The proportion of cows diagnosed with SCK was lower in this study compared to others [2,16,21,23] which showed that SCK was not a serious problem in the farms studied.…”
Section: Discussionmentioning
confidence: 51%
See 3 more Smart Citations