2011
DOI: 10.5851/kosfa.2011.31.1.115
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Beef Freshness Using Visible-near Infrared Reflectance Spectra

Abstract: The objective of this study was to develop models to predict freshness factors (total viable counts (TVC), pH, volatile basic nitrogen (VBN), trimethylamine (TMA), and thiobarbituric acid (TBA) values) and the storage period in beef using a visible and near-infrared (NIR) spectroscopic technique. A total of 216 beef spectra were collected during the storage period from 0 to 14 d at a 10°C storage. A spectrophotometer was used to measure reflectance spectra from beef samples, and beef freshness spectra were div… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

1
0
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(1 citation statement)
references
References 8 publications
1
0
0
Order By: Relevance
“…The total cell count and the count of coliform group bacteria in frozen foods are described in the Food Code as 5.00 log CFU/g and 1.00 log CFU/g or less, respectively [58]. In this study, the total cell count showed a tendency to increase with an increase in the storage period; the sample stored at −18 • C showed a slightly higher total cell count than that stored at −60 • C. This trend is the same as reported in many previous studies-the total cell count increases with an increase in the storage period, and the growth of microorganisms is inhibited with a decrease in the storage temperature [59][60][61]. The total cell count was not detected immediately after the sample was prepared, vacuum-packed, and heat sterilized at 94 • C for 40 min.…”
Section: Microbial Analysissupporting
confidence: 77%
“…The total cell count and the count of coliform group bacteria in frozen foods are described in the Food Code as 5.00 log CFU/g and 1.00 log CFU/g or less, respectively [58]. In this study, the total cell count showed a tendency to increase with an increase in the storage period; the sample stored at −18 • C showed a slightly higher total cell count than that stored at −60 • C. This trend is the same as reported in many previous studies-the total cell count increases with an increase in the storage period, and the growth of microorganisms is inhibited with a decrease in the storage temperature [59][60][61]. The total cell count was not detected immediately after the sample was prepared, vacuum-packed, and heat sterilized at 94 • C for 40 min.…”
Section: Microbial Analysissupporting
confidence: 77%